SIGLENT SPD1305X Quick Start Manual
SIGLENT SPD1305X Quick Start Manual

SIGLENT SPD1305X Quick Start Manual

Programmable linear
Hide thumbs Also See for SPD1305X:

Advertisement

SIGLENT
Quick Start
SPD1000X Programmable Linear DC
Power Supply
QS0501X-E02B
2018 SIGLENT TECHNOLOGIES CO.,LTD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPD1305X and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SIGLENT SPD1305X

  • Page 1 SIGLENT Quick Start SPD1000X Programmable Linear DC Power Supply QS0501X-E02B 2018 SIGLENT TECHNOLOGIES CO.,LTD...
  • Page 3: Copyright And Declaration

    Trademark Information SIGLENT is a registered trademark of SIGLENT TECHNOLOGIES. Declaration  SIGLENT products are protected by patent law in and outside of the Peoples Republic of China  SIGLENT reserved the right to modify or change the specifications and price of the product ...
  • Page 4: General Safety Summary

    SIGLENT General Safety Summary Please review the following safety precautions carefully to avoid personal injury or damage to this product or any product connected to it. To prevent potential danger, please use the instrument as specified. Use the proper power cord Only the power cord designed for the instrument and authorized by the local country should be used.
  • Page 5 SIGLENT instrument, which can lead to further damage. Please keep proper ventilation and check the fan and air-vents regularly when using the instrument. Operate condition Location: indoor, no strong light, almost no interfering pollution Relative humidity: < 80% Altitude:< 2000 m Temperature: 0℃...
  • Page 6 SIGLENT General Safety Summary Terms may appear on the product: DANGER: Indicates direct injury or hazard that may happen. WARNING: Indicates potential injury or hazard that may happen. CAUTION: Indicates potential damage to the instrument or other property that may happen.
  • Page 7: Spd1000X Brief Introduction

    TFT-LCD screen, programmable output, and real time measurement graphing. The SPD1168X has a maximum output values of 16 V/8 A, while the SPD1305X has a maximum output values of 30 V/5 A. Both models have remote sense capability, output short circuit and overload protection.
  • Page 8 SIGLENT μ  Fast Transient Response Time: < 50  Maximum resolution of 1mV/ 1mA with 5-bit voltage and 4-bit current display.  Timer function sequences pre-set output values  High resolution 2.8 inch TFT LCD(240*320 pixels)  Two output modes: two-wire output and remote sense compensation function (maximum compensation up to 1V) ...
  • Page 9: Table Of Contents

    General Safety Summary ......IV SPD1000X Brief Introduction ......V General Inspection........1 The Front Panel..........2 The Rear Panel ..........5 Connect Power ..........7 User Interface ..........9 Output Inspection .........11 Fuse Replacement ........12 Troubleshooting ......... 13 Contact SIGLENT ........14 SPD1000X Quick Start VII...
  • Page 10 SIGLENT VIII SPD1000X Quick Start...
  • Page 11: General Inspection

    The consigner or carrier is responsible electrical and for damages to the instrument resulting from shipment. SIGLENT will not provide free maintenance or replacement for shipping damages. 2. Inspect the instrument If there is damage, defects, or failures in electrical and mechanical tests of the product, please contact your nearest SIGLENT sales representative.
  • Page 12: The Front Panel

    SIGLENT The Front Panel Figure 2: The front panel of the SPD1168X 2 SPD1000X Quick Start...
  • Page 13 SIGLENT 1. LCD 2.8 inch TFT display. It is used to display system parameter settings, system output state, menu options, prompt messages, etc. 2. Knob When setting parameters, rotate the knob to increase or decrease the value of the digit at the cursor.
  • Page 14 SIGLENT Press the button for a longer period to enter the storage function system. Press the Fine button for a short period to choose the subproject, press the Fine button for a longer period to determine the choice. Press the button to enable/disable the remote sense function.
  • Page 15: The Rear Panel

    SIGLENT The Rear Panel Figure 3: The rear panel of the SPD1000X 1. Warning message To note to ground the instrument and non-professional personnel should not disassemble the instrument and so on. SPD1000X Quick Start...
  • Page 16 SIGLENT 2. AC input voltage description The frequency、voltage and the specified fuse have to match with AC input . 3. AC power socket The socket of AC input power. 4. Fuse The needed specified fuse relate to the input voltage(Please refer to the “AC input voltage description“)
  • Page 17: Connect Power

    SIGLENT Connect power The power supply supports a variety of AC line power input values. For each line voltage, the rear panel voltage selector settings are different, as shown in table 1 below. Table 1: AC input line power specifications...
  • Page 18 SIGLENT Please check whether the fuse matches the actual input voltage according to the "Input Power Requirements" at the rear panel of the instrument. 4. Connect the power Connect the instrument to AC power supply using the power cord provided in the accessories. Then press the button to turn on the power.
  • Page 19: User Interface

    SIGLENT User interface Figure 4: The user interface 1. Channel output state 2. Remote sense mode 3. LAN connection icon 4. USB connection icon 5. Output mode SPD1000X Quick Start 9...
  • Page 20 SIGLENT 6. Output programmed values 7. Measured output values 8. Timer state 10 SPD1000X Quick Start...
  • Page 21: Output Inspection

    (CV) mode. You can check the voltage range of SPD1168X by adjusting the voltage setpoint from the minimum (0 V) to the maximum value (16 V) and the voltage range of SPD1305X by adjusting the voltage setpoint from the minimum (0 V) to the maximum value (30 V).
  • Page 22: Fuse Replacement

    SIGLENT Fuse Replacement The specifications of the fuse are relative to the actual input line voltage, shown in the table below. You also can refer to the rear panel “input power requirement”. Input voltage Fuse specification 100/120 VAC T6.3A 220/230 VAC T3.15A...
  • Page 23: Troubleshooting

    SIGLENT Troubleshooting Here are some common failures and their solutions. If the problem persists after following the listed steps, please contact SIGLENT. 1. The instrument cannot start up. (1) Check whether the power is correctly connected. (2) Check whether the power switch at the front panel is really on.
  • Page 24: Contact Siglent

    SIGLENT Contact SIGLENT America SIGLENT Technologies America, Inc 6557 Cochran Rd Solon, Ohio 44139 Tel: 440-398-5800 Toll Free:877-515-5551 Fax: 440-399-1211 info@siglent.com www.siglentamerica.com Headquarters SIGLENT TECHNOLOGIES CO., LTD. Blog No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao’an District, Shenzhen, 518101, China.