SIGLENT SPD3303S Quick Start Manual
SIGLENT SPD3303S Quick Start Manual

SIGLENT SPD3303S Quick Start Manual

Programmable dc power supply

Advertisement

Quick Start

SPD3303S/3303D
Programmable DC Power Supply
V1.0
2013 SIGLENT TECHNOLOGIES CO., LTD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPD3303S and is the answer not in the manual?

Questions and answers

Summary of Contents for SIGLENT SPD3303S

  • Page 1: Quick Start

    Quick Start SPD3303S/3303D Programmable DC Power Supply V1.0 2013 SIGLENT TECHNOLOGIES CO., LTD...
  • Page 2 1. SIGLENT TECHNOLOGIES CO., LTD. All Rights Reserved. 2. Information in this publication replaces all previous corresponding material. 3. SIGLENT reserves the right to change the specifications and price of the product. 4. Any way of copying, extracting and translating the content of the manual is not allowed without permission of SIGLENT.
  • Page 3: General Safety Summary

    The instrument is grounded through the protective terra conductor of the power cord. To avoid electric shock, the grounding conductor must be connected to the earth. Make sure that the instrument is properly grounded before any inputs or outputs. II SPD3303S/3303D Quick Start...
  • Page 4 Keep surface of the product clean and dry To avoid dust or moisture in the air influence the performance of the instrument , please keep surface of the product clean and dry. SPD3303S/3303D Quick Start III...
  • Page 5: Safety Terms And Symbols

    WARNING: Indicates potential injury or hazard that may happen. CAUTION: Indicates potential damage to the instrument or other property that may happen. Symbols may appear on the product: Hazardous Protective Warning Earth Power Vlotage Earth Ground Ground Switch IV SPD3303S/3303D Quick Start...
  • Page 6: Spd3303S/3303D Brief Introduction

    SIGLENT SPD3303S/3303D Brief Introduction SPD3303S/3303D Programmable DC Power Supply is convenient, flexible and multi-function. It has three independent outputs, two sets of adjustable voltage value and a fixed set of selectable voltage value of 2.5V, 3.3V, and 5V ,and it also provides output short circuit and overload protection at the same time.
  • Page 7: Table Of Contents

    2.9 Version information ............21 2.10 Upgrade firmware............. 22 Chapter 3 Remote control ............. 25 3.1 Command list ..............25 3.2 Command description ............26 Chapter 4 Specification..............32 Chapter 5 Troubleshooting ............34 Contact SIGLENT ..............35 VI SPD3303S/3303D Quick Start...
  • Page 8: Chapter 1 Quick Start

    Chapter 1 Quick Start In this chapter, we mainly introduce the panel and display of SPD3303S/3303D, as well as the new machine inspection and attentions at first use. Reading the following steps will give you a quick understanding on operation.
  • Page 9: Safety Considerations

    To ensure that the instrument can work normally, please conduct necessary inspection before using the SPD3303S/3303D. Input Power Requirement The SPD3303S/3303D allows a 50Hz/60Hz frequency, and four levels of AC power: 100V/120V/220V/230V. You can select wanted power voltage with the “DIP Switch ” at the rear panel according to the actual demand.
  • Page 10: The Front Panel

    CH3 DIP Switch Display Area Power Switch Model CH1 Output Terminal System parameter Ground Terminal configuration button Multi-function knob CH2 Output Terminal Fine Adjust button CV/CC indicator light Right/Left Direction button CH3 Output Terminal Channel Control button SPD3303S/3303D Quick Start 3...
  • Page 11 : Press the button to turn on/off the CH3 output. Other buttons : Press the button to open the fine tuning function and change the FINE parameters with the minimum step; : To move the cursor around. 4 SPD3303S/3303D Quick Start...
  • Page 12 The output terminals of CH1 、 CH2 and CH3 include positive terminal and negative terminal, and a common ground for CH1 and CH2 additional. Each channel has its own logo. The operation details are introduced in the follow-up ” control panel operation”. SPD3303S/3303D Quick Start 5...
  • Page 13 LOCK logo: It will display when the LOCK is turned on ○ USB logo: It will display when there is a USB connection; ○ Voltage value; ○ Current value; ○ Power value; ○ Timer lD: Timer state identification ○ Channel on/off logo; 6 SPD3303S/3303D Quick Start...
  • Page 14: The Rear Panel

    The DIP switch of the AC power and its identification . ○ The description of the AC input voltage ○ AC power socket ○ The fan air vents ○ CE certification mark ○ USB interface and identification SPD3303S/3303D Quick Start 7...
  • Page 15: Output Check

    Revolve the knob to set the voltage value to 32V; Revolve the knob to set the current value to 0A; Adjust the current parameters to check whether the current value can be changed from 0A to 3.2A. 8 SPD3303S/3303D Quick Start...
  • Page 16: Chapter 2 Control Panel Operation

    SIGLENT Chapter 2 Control panel operation In this chapter,the function and operation of SPD3303S/3303D control panel will be introduced in detail to giving you an all-around understanding of it, which will eventually lead to easier work. Brief introduction: Output summary...
  • Page 17: Output Summary

    SIGLENT 2.1 Output summary Summary SPD3303S/3303D have three independent outputs, two of which are adjustable in voltage value and the other one includes selectable 2.5V, 3.3V or 5.0V Independent/Parallel/Series SPD3303S/3303D have three output modes: independent、parallel and series, which can be selected through the track switch on the front panel.
  • Page 18: Ch1/Ch2 Independent Output

    Coarse adjusting: 0.1V or 0.1A each step. Fine adjusting: the least precision each step. 4. Open output :Press “ON/OFF” button to turn on the output, the corresponding indicator light gets lighted immediately and “CC” or “CV” is showed on the current interface. SPD3303S/3303D Quick Start 11...
  • Page 19: Ch3 Independent Mode

    When the current value is higher than 3A, the overload indicator light turns red and the working mode turns to CC from CV Note: “overload” does not mean abnormal operation. 12 SPD3303S/3303D Quick Start...
  • Page 20: Ch1/Ch2 Series Mode

    Coarse: 0.1V or 0.1A each step; Fine: the least precision each step; 4. Turn on CH1, and then set the output voltage/current value by revolving the multi-function knob; 5. Press “ON/OFF” button to open the output. SPD3303S/3303D Quick Start 13...
  • Page 21 SIGLENT Note: You can identify the current working state “CC” or ”CV” by referring to indicator light of CH1/CH2.(red means CV, green means CC). 14 SPD3303S/3303D Quick Start...
  • Page 22: Ch1/Ch2 Parallel Mode

    4. Press “ON/OFF” button to open the output. Note: You can identity the current working state “CC” or ”CV” by referring to indicator light of CH1/CH2.(red means CV, green means CC);In parallel mode, CH2 only works in CC mode. SPD3303S/3303D Quick Start 15...
  • Page 23 SIGLENT 16 SPD3303S/3303D Quick Start...
  • Page 24 4. Move the cursor to “RECALL”, and then press it to read the saved setup. Note: if you want to delete the file that has been saved, please go on with step 3 above, select “DELETE” and then press it. SPD3303S/3303D Quick Start 17...
  • Page 25: Timer

    3. Move the cursor to select the wanted parameter(voltage/current /time) by pressing the direction button; 4. Revolve the multi-function knob to set the corresponding value and then press it. 5. Press “Timer” again to exit current interface. 18 SPD3303S/3303D Quick Start...
  • Page 26 Note: If press the “TIMER” button when the timer is running, then you can observe the decreasing of the time ,and the changes of the curve .The Timer will automatically turn off when the time reduces to 0. SPD3303S/3303D Quick Start 19...
  • Page 27 3. Press CH1/CH2 “ON/OFF” button to turn on CH1/CH2 channel, the corresponding indicator light turns bright immediately and observe real-time changing current voltage/current. Waveform interface: Note: Yellow line means voltage, green line means current, and axis ordinate means voltage or current value (0~30V/0~3A). 20 SPD3303S/3303D Quick Start...
  • Page 28: Version Information

    SIGLENT 2.9 Version information Press “LOCK” button quickly to enter Version Information interface, which is shown below: SPD3303S/3303D Quick Start 21...
  • Page 29: Upgrade Firmware

    USB firmware upgrade dialogue. See figure 1: F igure 1 3. Figure 2 shows the firmware upgrade dialogue. Click file choosing icon , and then select the file to be upgraded which must have a postfix ugf. 22 SPD3303S/3303D Quick Start...
  • Page 30 Figure 2 Figure 3 4. As it shows in figure 4, click Upgrade button to start upgrading. The upgrade is finished when the progress bar complete and the instrument will run the version after upgrade. Figure 4 SPD3303S/3303D Quick Start 23...
  • Page 31 1. Press the knob before powering on the instrument, and the turn on the instrument and it will enter the guide procedure mode. 2. After enter the guide procedure mode, the upgrade method is the same as the first one. 24 SPD3303S/3303D Quick Start...
  • Page 32: Chapter 3 Remote Control

    6. MEASure:CURRent? 7. MEAsure:VOLTage? 8. MEASure:POWEr? 9. [SOURce:]CURRent <current> 10. [SOURce:]CURRent ? 11. [SOURce:]VOLTage <volt> 12. [SOURce:] VOLTage? 13. OUTPut 14. OUTPut:TRACk 15. OUTPut:WAVE 16. TIMEr:SET 17. TIMEr:SET? 18. TIMEr 19. SYSTem:ERRor? 20. SYSTem:VERSion? 21. SYSTem: STATus? SPD3303S/3303D Quick Start 25...
  • Page 33: Command Description

    Query the manufacturer, product type, series NO. and software version. Return Info Manufacturer, product type, series NO., software version. Example Siglent, SPD3303S, SPD00001130025, 1.01.01.02. 2. * SAV Command format *SAV <name> Description Save current state in nonvolatile memory with the specified name.
  • Page 34 MEASure: VOLTage? CH1 Return Info 30.000 Command format MEASure: POWEr? < CH1|CH2> Description Query power value for specified channel, if there is no specified channel, query the current channel. Example MEASure: POWEr? CH1 Return Info 90.000 SPD3303S/3303D Quick Start 27...
  • Page 35 <SOURce>:={CH1 | CH2} Description Set voltage value of the selected channel Example CH1: VOLTage 25 Command format <SOURce>:CURRent? <SOURce>:={CH1 | CH2} Description Query the voltage value of the selected channel. Example CH1: VOLTage? Return Info 25.000 28 SPD3303S/3303D Quick Start...
  • Page 36 OUTPut: WAVE CH1, ON TIMEr Command format TIMEr: SET <SOURce>, <secnum>, <volt>, <curr>, <time> <SOURce>:={CH1 | CH2}; < secnum >;=1 to 5; Description Set timing parameters of specified channel Example TIMEr: SET CH1, 2, 3, 0.5, 2 SPD3303S/3303D Quick Start 29...
  • Page 37 TIMEr CH1, ON SYSTem Command format SYSTem: ERRor? Description Query the error code and the information of the equipment. Command format SYSTem: VERSion? Description Query the software version of the equipment. Example SYSTem: VERSion? Return Info 1.01.01.02 30 SPD3303S/3303D Quick Start...
  • Page 38 1: CH1 ON 0: CH2 OFF 1: CH2 ON 0: TIMER1 OFF 1: TIMER1 ON 0: TIMER2 OFF 1: TIMER2 ON 0: CH1 digital display; 1: CH1 waveform diplay 0: CH2 digital display; 1: CH2 waveform diplay SPD3303S/3303D Quick Start 31...
  • Page 39: Chapter 4 Specification

    Voltage:±(0.5% of reading + 1 digital) Current:± (0.5% of reading + 1 digital) Read precision SPD3303S: Voltage:±(0.03% of reading + 10mV) Current:± (0.3% of reading + 10mA) SPD3303D Voltage:±(0.5% of reading + 1 digital) Current:± (0.5% of reading + 1 digital) 32 SPD3303S/3303D Quick Start...
  • Page 40 ≤2000 m Environment 0 ~ 40℃ temperature Comparative humidity Ⅱ Installation level Pollution level Storage Environment -10 ~ 70℃ temperature environment Comparative humidity ≤ 70% Power supply AC 100V/120V/220V/230V±10%, 50/60HZ Volume 275mm x 225mm x 136mm Weight SPD3303S/3303D Quick Start 33...
  • Page 41: Chapter 5 Troubleshooting

    (For instance: the rating of air switch B and C should be respectively over 16A and 10A). If the failure still exits beyond the reason, check if there is a short circuit, or return it to the factory to have it repaired by qualified personnel. 34 SPD3303S/3303D Quick Start...
  • Page 42: Contact Siglent

    SIGLENT Contact SIGLENT MTR Add: 3/F, Building 4, Antongda Industrial Zone, 3rd Liuxian Road, 68 District, Baoan District, Shenzhen, P.R. CHINA Tel: +86-755-36615186 E-mail:sales@siglent.com http://www.siglent.com SPD3303S/3303D Quick Start 35...

This manual is also suitable for:

Spd3303d

Table of Contents