HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. To adjust the reed
switch, first unplug the power adapter. Then, remove
the parts described below.
First, remove the
six M4 x 10mm
70
Screws (70) and
gently remove
the Resistance
Handle (9).
See EXPLODED DRAWING B on page 31. Locate
the Right and Left Shields (7, 8). Remove the four
M4 x 19mm Screws (69) and the ten M4 x 16mm
Screws (68) from the Right and Left Shields. Then,
gently remove the Right and Left Shields.
9
70
Next, locate the Reed Switch (47). Turn the Left Fan
(4) until a Magnet (85) is aligned with the Reed Switch.
Then, slightly loosen the two indicated M4 x 19mm
Screws (69), slide the Reed Switch slightly closer to or
away from the Magnet, and then retighten the Screws.
47
85
69
Plug in the power adapter, and then turn the Left Fan
(4) so that the Magnet (85) passes the Reed Switch
(47) repeatedly. Repeat the actions described above
until the console displays correct feedback.
When the reed switch is correctly adjusted, reattach
the parts that you removed.