3. Install the new drive CRU.
4. Check the drive LEDs.
Working with cards and boards
Before you begin
v Read the safety and handling guidelines provided in "Appendix D. Safety notices" on page 51.
v Ensure that your current system configuration is working properly.
v Back up all important data before you make changes to storage devices, such as hard disk drives.
The storage-unit bridge card, switch card, and ESM boards are customer
replaceable units (CRUs). This section contains step-by-step instructions for
removing and replacing each device.
Replacing a bridge card
To replace the bridge card CRU in the storage unit, follow the instructions for
removing the bridge card and installing a bridge card.
a. Gently push the drive CRU into the empty bay until the tray handle 2
touches the storage unit tray.
b. Push the tray handle 2 down into the closed (latched) position.
a. When a drive is ready for use, the green activity LED and the amber fault
LED are off.
b. If the amber fault LED is on, remove the drive from the unit and wait 10
seconds; then, reinstall the drive.
ServeRAID information In some cases, the ServeRAID controller will automatically reset
the drive to the Hot Spare or Rebuild state. If the drive state change does not occur
automatically (amber LED stays lit), refer to your ServeRAID documentation for information
about manually changing the state of the drive from the current state to another state, such
as Hot Spare or Ready. The amber LED should turn off within 10 seconds after the
drive-state change.
Chapter 3. Installing and replacing devices
23