Troubleshooting

You can use these charts to find solutions to problems that have definite symptoms.
Problem
Component Possible
indicator
Amber LED on
Drive CRU
ESM board
Front panel
Amber LED on
Power-
and green LED
supply
off
CRUs
Amber and
Power-
green LEDs on
supply
CRUs
All green LEDs
All CRUs
off
Amber LED
Drive CRUs Drive rebuild
flashing
Power
supply CRU
Amber LED on
Power
and green dc
supply CRU
power LED off
© Copyright IBM Corp. 2001
Product warranties" on page 41.
Possible solutions
cause
Drive failure
Replace the failed drive. See "Replacing hot-swap drives" on
page 22.
Board failure
Replace failed board. See "Replacing an ESM board" on page 25.
General
Indicates that a Fault LED somewhere on the storage unit has been
machine fault
turned on. Check for amber LEDs and CRUs. See "Rear controls,
indicators, and connectors" on page 5
Power is
Turn on all power supplies. See "Rear controls, indicators, and
turned off
connectors" on page 5.
Power supply
Replace the failed power supply CRU. See "Replacing an ESM
failure
board" on page 25.
The storage
Check that all storage unit power cables are plugged in and the
unit is turned
power is on. If applicable, check that the main circuit breakers for the
off
rack are turned on.
If the external switch 1 is set to Off, the SCSI controller must be
cabled to the storage unit and turned on. See "External option
switches" on page 11.
AC power
Check the main circuit breaker and ac outlet.
failure
Power supply
Replace the power supply CRU. See "Removing a hot-swap power
failed
supply/fan unit" on page 26.
Midplane
Have the storage unit serviced.
failure
No corrective action is needed.
or identity is
in process
Fan failure
Replace the power supply CRU.
Power supply
If the power switch is on, replace the power supply CRU. See
failure
"Removing a hot-swap power supply/fan unit" on page 26.