Working With Cards And Boards - IBM Netfinity EXP300 Installation And User Manual

Hide thumbs Also See for Netfinity EXP300:
Table of Contents

Advertisement

Working with cards and boards

3. Install the new drive CRU.
a. Gently push the drive CRU into the empty bay until the tray handle 2
touches the expansion unit tray.
b. Push the tray handle 2 down into the closed (latched) position.
4. Check the drive LEDs.
a. When a drive is ready for use, the green activity LED and the amber fault
LED are off.
b. If the amber fault LED is on, remove the drive from the unit and wait 10
seconds; then, reinstall the drive.
ServeRAID information
In some cases, the ServeRAID controller will automatically reset the drive to the
Hot Spare or Rebuild state. If the drive state change does not occur automatically
(amber LED stays lit), refer to your ServeRAID documentation for information
about manually changing the state of the drive from the current state to another
state, such as Hot Spare or Ready. The amber LED should turn off within 10
seconds after the drive-state change.
Before you begin
Read the safety and handling guidelines provided in "Safety" on page v and
"Handling static-sensitive devices" on page 25.
Ensure that your current system configuration is working properly.
Back up all important data before you make changes to storage devices, such as
hard disk drives.
The expansion-unit bridge card, switch card, and ESM boards are customer
replaceable units (CRUs). This section contains step-by-step instructions for removing
and replacing each device.
Chapter 3. Installing and replacing devices
29

Advertisement

Table of Contents
loading

Table of Contents