Time Clock Regeneration Valves
In normal operation the Time of Day Display may be viewed at all times. The control operates for a preset number of
days between Regeneration cycles. When the number of days since the last Regeneration reaches the preset
number of days, a Regeneration cycle initiates at the preset Regeneration Time.
Flow Meter Equipped Valves –General
Flow meter equipped valves calculate the volume of water that the system can treat between Regeneration cycles
based on the system capacity which is preset by the system manufacturer in a Master Programming Mode and the feed
water hardness which is programmed in the Start-Up procedure safety factor (Master Mode only). The remaining
system capacity displays in gallons or liters. The display has a range of 0 to 9999 (gallons or liters). I the remaining
capacity exceeds 9999 liters when in the Metric Mode, then the display changes to millions of liters and a letter t is
displayed as the first digit. The display then has a range of t1.0 (1,000,000) to t1.9 (1,900,000).
Flow Meter Equipped Valves –Immediate Regeneration Mode The Time Of Day display alternates with the
Volume Remaining display in gallons or liters. The Meter dot flashes
in direct relation to the water flow rate through the unit. As treated water is used, the Volume Remaining display
counts down from a maximum value to zero and initiates a Regeneration cycle.
INSTALLING 7000
10