6 Installation
6
Installation
6.1
Positioning the appliance
Fig.5
200
MW-L000565-2
6.2
Levelling the domestic hot water tank
Fig.6
1
6.3
Putting the domestic hot water sensor in place
Fig.7
14
BPB 150...501
1. Remove the packaging from the tank but leave the tank on the
shipping pallet.
2. Remove the protective packaging.
3. Remove the three screws securing the tank to the pallet.
4. Lift the tank and place it in its final position, respecting the distances
shown on the diagram.
The domestic hot water tank is levelled using the three feet (supplied in
the bag) to be screwed to the bottom of the domestic hot water tank.
1. Screw the three adjustable feet to the bottom of the domestic hot
water tank.
2. Level the appliance using the adjustable feet.
2
L000382-A
1. Position the probe in the sensor tube, using the sensor tube
separator.
2
1
2. Check that the probes are correctly positioned in the sensor tube.
3. Check the mounting of the sensor tube separator.
3
MW-C003702-2
Caution
Have 2 people available.
Handle the appliance with gloves.
Caution
Leave 500 mm of clearance around the anodes to facilitate
access.
Adjustment range: 10 mm.
Use metal blocks under the feet of the tank if necessary.
Caution
Do not place the blocks on the exterior sides of the domestic hot
water tank.
Important
The sensor tube separator is provided in the documentation bag.