3 Technical specifications
3
Technical specifications
3.1
Homologations
3.2
Technical data
Tab.1
Primary circuit: (Ex
changer)
Maximum operating tem
perature
Maximum operating
pressure
Exchanger capacity
Exchange surface
Water resistance at 3
3
m
/h
Secondary circuit (do
mestic water)
Maximum operating tem
perature
Maximum operating
pressure
Water capacity
Weight
Shipping weight (gross)
Weight of the domestic
hot water tank (net)
Performances related to
the boiler type
Output exchange
(1)
8
BPB 150...501
3.1.1
This product complies with the requirements of the following European
Directives and Standards:
3.1.2
This product conforms to the requirements of European Directive
2014/68/UE, article 4, paragraph 3, on pressure equipment.
3.1.3
This product conforms to the requirements of European Directive
2009/125/EC on the ecodesign of energy-related products.
3.2.1
Unit
BPB 150
°C
110
MPa (bar)
1 (10)
litres
5.6
0.84
2
m
kPa
12
°C
95
MPa (bar)
1 (10)
litres
145
kg
68
kg
51,5
kW
29
Certifications
Low Voltage Directive 2014/35/EU
Generic standard: EN 60335-1
Relevant standards: EN 60335-2-40, EN 60335-2-21
Electromagnetic Compatibility Directive 2014/30/EU
Generic standards: EN 61000-6-3, EN 61000-6-1
Relevant Standard: EN 55014
2014/68/UE Directive
Ecodesign Directive
Specifications of the domestic hot water tank
BPB 200
BPB 300
110
110
1 (10)
1 (10)
8.1
11.4
1.20
1.70
14
17
95
95
1 (10)
1 (10)
195
290
90
119
78
106,5
39
54
BPB 401
BPB 501
110
110
1 (10)
1 (10)
14.8
20.8
2.20
3.10
20
26
95
95
1 (10)
1 (10)
385
485
149,5
184,5
137
172
68
86
300027336 - v06 - 13062019