Installation Shutdown; Frost Protection - DeDietrich Innovens MCA 25 BIC User Manual

Wall-hung gas condensing boilers
Table of Contents

Advertisement

MCA 25/28 BIC
User level - Menu #TIME PROGRAM
Day
TIME PROG.DHW Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Monday
TIME PROG.AUX
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
4.4

Installation shutdown

4.5

Frost protection

15/06/12 - 300022162-001-01
Comfort periods / Filling enabled:
P1
P2 _______________ P3 _______________ P4 _______________
_______________
When the heating water temperature in the boiler falls by too much,
the integrated protection system in the boiler starts up. This protection
functions as follows:
4 If the water temperature is lower than 7°C, the heating pump starts
up.
4 If the water temperature is lower than 4°C, the boiler starts up.
4 If the water temperature is higher than 10°C, the boiler shuts down
and the circulation pump continues to run for a short time.
4 If the water temperature in the storage tank is less than 7°C, it is
reheated to its set point.
CAUTION
Do not switch off the mains supply to the appliance. If the
central heating system is not used for a long period, we
recommend activating the HOLIDAYS mode (to ensure
the anti-grip of the heating pump).
4. Operating the boiler
24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Innovens mca 28 bic

Table of Contents