Connecting to the Network

1. Insert the 8-pin connector of the RJ48C network cable into the network interface.
2. Insert the other end of the cable into the RJ48C modular jack.
P
O
R
T
1
NOTE:
After connecting the network cable, wait a few minutes to allow
Auto-Configuration a chance to discover the frame relay characteristics
and DLCIs.
Verification Check:
-
Check the Network LEDs. Is the Sig (signal) LED on, and are the OOF (out of
frame), and ALM (alarm) LEDs off? If so, the network interface is set up correctly
and is operational. If not, make sure both ends of the network cable are properly
seated and secured.
-
Verify that the network physical options are configured correctly.
Main Menu → Configuration → Network → Physical
-
Check Health and Status messages in the left column of the System and Test
Status screen to see the LMI status, to verify that LMI is up.
Main Menu → Status → System and Test Status
If LMI Down, Net1-FR1 appears for more than three minutes, or any other
network-related status message appears, refer to the status information in
Operation and Maintenance of the User's Guide for possible reasons for the
messages and what can be done to resolve the problem.
If the unit does not have ISDN backup capability, proceed to Configuring SNMP Trap