Flush Mount Enclosure - HEATSTRIP Elegance THE1800EU Operation, Installation, And Maintenance Manual

Table of Contents

Advertisement

Available languages

Available languages

Flush Mount Enclosure

The Flush Mount Enclosure is an ideal way to neatly install the HEATSTRIP Elegance into a ceiling. They are
available for all HEATSTRIP Elegance models, and are supplied as a one-piece unit for mounting of heaters. Flush
mounting can be used with plaster or wood lined or concrete ceiling materials.
An ideal mounting height is 2.5m-2.7m, with a maximum ceiling height of 3.0m in an outdoor enclosed environment.
Maximum mounting heights should be strictly followed, otherwise the performance of the units may be reduced.
Safety
Do not allow any cables, furnishings, flammable materials or other items come in contact with any surface of the Flush
Mount Enclosure.
The Flush Mount Enclosure needs to be installed as per the installation instructions paying special attention to the
minimum clearances. The heater needs to be mounted on a rigid bracket or fixing.
Maintenance Flush Mount Enclosure
The Flush Mount Enclosure is made from durable materials, however regular care and maintenance of your product
will help prolong its life.
It is recommended that you wipe down your Flush Mount Enclosure and with a soft cloth gently wipe the surfaces of
the Flush Mount Enclosure with a mild detergent to remove the built up contaminants from the environment. Then with
a clean cloth ensure all detergent is removed.
All chemicals in the atmosphere including cigarette smoke, pollution etc. will tarnish the surface of the Flush Mount
Enclosure. In this case, additional cleaning and maintenance may be required. The cleaning process at least every
three months will reduce the amount of build up and keep it looking as best it can. If the Flush Mount Enclosure is in a
corrosive environment eg. salt spray, we recommend that you clean the Flush Mount Enclosure every week.
Before cleanings or inspection activity, the heater must be switched off and cooled down completely.
Do not use any abrasive materials or products to clean the Flush Mount Enclosure, this includes solvents, citrus
based cleaners or other harsh cleaning products.
When handling the Flush Mount Enclosure, ensure that your hands are clean or that you use clean gloves as grease
or dirt can mark the surface of the heater.
Do not use high pressure water to clean Flush Mount Enclosure. It is not recommended to hose down the Flush
Mount Enclosure and heater as water may get into the roof cavity.