Technical Data, Mains Supply 3 X 380 - 460 V - Danfoss VLT 6000 HVAC Manual

Hide thumbs Also See for VLT 6000 HVAC:
Table of Contents

Advertisement

Technical data, mains supply 3 x 380 - 460 V

According to international requirements
Output current
I
VLT, MAX
I
VLT, MAX
Output
Typical shaft output
Typical shaft output
Max. cable cross-section
to motor
Max. input current
Max. cable cross-section,
power
Max. pre-fuses
Mains contactor
Efficiency
3)
Weight IP 20
Weight IP 54
Power loss at max. load. [W]
Enclosure
Mains supply 3 x 380 - 460 V
According to international requirements
Output current
I
VLT, MAX
I
VLT, MAX
Output
Typical shaft output
Typical shaft output
Max. cable cross-section
to motor and DC-bus
Min. cable cross-section
to motor and DC-bus
Max. input current
Max. cable cross-section,
power
Max. pre-fuses
Efficiency at rated frequency
Weight IP 20
Weight IP 54
Power loss at max. load.
Enclosure
1. If UL/cUL is to be complied with, pre-fuses type Bussmann KTS-R or similar must be used. In the remainder of the world, the first-
mentioned pre-fuses must be used. These pre-fuses must be semi-conductor fuses of the gL type. The fuses must be placed to
protect a circuit capable of supplying max. 100,000 amps rms (symmetrical), 500 V maximum.
2. American Wire Gauge.
3. Measured using 30 m screened/armoured motor cable at rated load and rated frequency.
4. Min. cable cross-section is the smallest cable cross-section allowed to be fitted on the terminals.
Always comply with national and local regulations on min. cable cross-section.
46
VL
VL
VL
VLT type
VL
T type
T type
T type
T type
I
[A] (380-415 V)
VLT,N
(60 s) [A] (380-415 V)
I
[A] (440-460 V)
VLT,N
(60 s) [A] (440-460 V)
S
[kVA] (400 V)
VLT,N
S
[kVA] (460 V)
VLT,N
P
[kW]
VLT,N
P
[HP]
VLT,N
[mm
2
/AWG]
I
[A] (380 V)
L,N
I
[A] (460 V)
L,N
[mm
2
]/[AWG]
2 )
[A]/UL
1 )
[A]
[Danfoss type]
[AC value]
[kg]
[kg]
Total
VLT type
VL
VL
VL
VLT type
VL
T type
T type
T type
T type
6016
6016
6016
6016
6016
I
[A] (380-415 V)
24.0
VLT,N
(60 s) [A] (380-415 V)
26.4
I
[A] (440-460 V)
21.0
VLT,N
(60 s) [A] (440-460 V)
23.1
S
[kVA] (400 V)
17.3
VLT,N
S
[kVA] (460 V)
16.7
VLT,N
P
[kW]
11
VLT,N
P
[HP]
15
VLT,N
[mm
2
/AWG]
16/6
4)
[mm
2
/AWG]
10/8
I
[A] (380 V)
32.0
L,N
I
[A] (460 V)
27.6
L,N
[mm
2
]/[AWG]
16/6
[A]/UL
1 )
[A]
63/40
0.96
[kg]
23
[kg]
48
[W]
419
IP 20/IP 54
®
VLT
6000 HVAC
6002
6002
6002
6002
6002
6003
6003
6003
6003
6003
6004
6004
6004
6004
6004
6005
6005
6005
6005
6005
3.0
4.1
5.6
7.2
3.3
4.5
6.2
7.9
3.0
3.4
4.8
6.3
3.3
3.7
5.3
6.9
2.2
2.9
4.0
5.2
2.4
2.7
3.8
5.0
1.1
1.5
2.2
3.0
1.5
2
3
-
4/10
4/10
4/10
4/10
2.8
3.8
5.3
7.0
2.5
3.4
4.8
6.0
4/10
4/10
4/10
4/10
16/6
16/10
16/10
16/15
CI 6
CI 6
CI 6
CI 9
AC-3
AC-3
AC-3
AC-3
0.96
8
8
8,5
8,5
11.5
11.5
12
12
67
92
110
139
Bookstyle IP 20/Compact IP 20/IP 54
(Bookstyle IP 20 is available in the VLT 6002-6011 power range)
6022
6022
6022
6022
6022
6027
6027
6027
6027
6027
6032
6032
6032
6032
6032
32.0
37.5
44.0
35.2
41.3
48.4
27.0
34.0
40.0
29.7
37.4
44.0
23.0
27.0
31.6
21.5
27.1
31.9
15
18.5
22
20
25
30
16/6
16/6
16/6
10/8
10/8
10/8
32.0
37.5
44.0
27.6
34.0
41.0
16/6
16/6
16/6
63/40
63/50
63/60
23
23
30
48
48
51
559
655
768
MG.60.B1.02 - VLT is a registered Danfoss trade mark
6006
6006
6006
6006
6006
6008
6008
6008
6008
6008
6011
6011
6011
6011
6011
10.0
13.0
16.0
11.0
14.3
17.6
8.2
11.0
14.0
9.0
12.1
15.4
7.2
9.3
11.5
6.5
8.8
11.2
4.0
5.5
7.5
5
7.5
10
4/10
4/10
4/10
9.1
12.2
15.0
8.3
10.6
14.0
4/10
4/10
4/10
25/20
25/25
35/30
CI 12
CI 5
CI 6
AC-3
AC-1
AC-1
10,5
10,5
10,5
14
14
14
198
250
295
6042
6042
6042
6042
6042
6052
6052
6052
6052
6052
6062
6062
6062
6062
6062
61.0
73.0
90.0
67.1
80.3
99.0
52.0
65.0
77.0
57.2
71.5
84.7
43.8
52.5
64.7
41.4
51.8
61.3
30
37
45
40
50
60
35/2
35/2
50/0
10/8
10/8
16/6
60.0
72.0
89.0
53.0
64.0
77.0
35/2
35/2
50/0
80/80
100/100
125/125
30
48
48
61
67
70
1065
1275
1571