11.2

Operating modes

The following table provides an overview of the DDLS 200 operating modes.
Operating
Description
mode
Automatic,
Normal operation
AUT LED illu-
minates
Manual,
Adjustment operation,
MAN LED
cut-off threshold on higher level
illuminates
Adjust, ADJ
Adjustment operation,
LED illumi-
cut-off threshold on higher level
nates
Changing the operating mode
AUT –> MAN Press the operating mode button for more than 2 seconds.
Only the device on which the button was pressed switches to the "Manual" operating
mode (MAN LED illuminates).
MAN –> ADJ Press the operating mode button on one of the two devices.
Both devices switch to the "Adjust" operating mode (both ADJ LEDs illuminate) when
both were previously in the "Manual" operating mode.
ADJ –> MAN Press the operating mode button on one of the two devices.
Both devices switch to the "Manual" operating mode (both MAN LEDs illuminate).
MAN –> AUT Press the operating mode button for more than 2 seconds.
Only the device on which the button was pressed switches to the "Automatic" operat-
ing mode (AUT LED illuminates).
Note!
If, while in the AUT operating mode, the operating mode button is pressed for longer than
13s, the device switches to a special diagnostic mode. The AUT , MAN and ADJ LEDs illu-
minate simultaneously (see chapter 13.2 "Diagnostic mode" on page 65).
To switch to the "Adjust" (ADJ) operating mode, both devices belonging to a transmission
path must first be in the "Manual" (MAN) operating mode. It is not possible to switch directly
from the "Automatic" to the "Adjust" operating mode or vice versa.
Leuze electronic
Commissioning / Operation (all device models)
Optical data
transmission
Active
Active
Separated
DDLS 200
Bar graph assignment
Its own receiving level,
display of the alignment quality of
the opposing device
Its own receiving level,
display of the alignment quality of
the opposing device
Receiving level of the opposing
device,
display of the alignment quality of
own device