Ethernet
DDLS 200 between terminal/PLC and terminal/PLC
Terminal / PLC
Crossover cable
Figure 10.7:DDLS 200 between terminal/PLC and terminal/PLC

10.4.1 Assignment of the RJ45 and M12 Ethernet cables

For the Ethernet models of the DDLS 200, the following pin assignments apply for the RJ45 and M12
connection cables.
RJ45 to RJ45 - 1 : 1
Signal
Function
TD+
Transmit Data +
TD-
Transmit Data -
RD+
Receive Data +
RD-
Receive Data -
RJ45 to RJ45 - "Crossover"
Signal
Function
TD+
Transmit Data +
TD-
Transmit Data -
RD+
Receive Data +
RD-
Receive Data -
M12 plug - D-coded with open cable end
Signal
Function
TD+
Transmit Data +
TD-
Transmit Data -
RD+
Receive Data +
RD-
Receive Data -
54
Optical data transmission
Core color
yellow
orange
white
blue
Core color
yellow
orange
white
blue
Core color
yellow
orange
white
blue
DDLS 200
Crossover cable
Pin RJ45
1 / TD+
<–>
2 / TD-
<–>
3 / RD+
<–>
6 / RD-
<–>
Pin RJ45
1 / TD+
<–>
2 / TD-
<–>
3 / RD+
<–>
6 / RD-
<–>
Pin M12
1 / TD+
<–>
3 / TD-
<–>
2 / RD+
<–>
4 / RD-
<–>
Leuze electronic
Terminal / PLC
Pin RJ45
1 / TD+
2 / TD-
3 / RD+
6 / RD-
Pin RJ45
3 / RD+
6 / RD-
1 / TD+
2 / TD-
Strand
YE
OG
WH
BU