Leuze electronic DDLS 200 Technical Description page 42

Bus-capable optical data transmission
Hide thumbs Also See for DDLS 200:
Table of Contents

Advertisement

DeviceNet / CANopen
BUS OUT
V+
2
1
Drain
4
CAN_L
CAN_H
M12 socket
(A-coded)
Figure 9.8:Assignment M12 connector BUS OUT
Via the selector switch S2, the bus transceiver can optionally be supplied via Power or V+ / V-.
S2 = Vin (default) bus transceivers are supplied internally
S2 = BUS, bus transceivers are supplied via V+/V-.
Attention!
The supply voltage V+ / V- is 11 ... 25VDC.
Termination
Note!
If the CANopen or DeviceNet network begins or terminates at the DDLS 200 (not a continu-
ing bus), the BUS OUT connection must be terminated with the TS01-5-SA terminator plug
(Part No. 50040099), which is available as an option.
In this case, please also order the TS 01-5-SA terminator plug.
40
BUS OUT (5-pin M12 socket, A-coded)
Pin
1
2
3
V-
3
4
5
Thread
Name
Drain
Shield
Positive supply bus transceiver
V+
(switch S2 = bus)
Negative supply bus transceiver
V-
(switch S2 = bus)
CAN_H
Bus signal High
CAN_L
Bus signal Low
FE
Functional earth (housing)
DDLS 200
Remark
Leuze electronic