Led Indicators Interbus 2Mbit/S Fiber-Optic Cable - Leuze electronic DDLS 200 Technical Description

Bus-capable optical data transmission
Hide thumbs Also See for DDLS 200:
Table of Contents

Advertisement

Note!
The delay time of a light path is approx. 2.5 µs.
7.3

LED indicators INTERBUS 2Mbit/s fiber-optic cable

In addition to the indicator and operating elements present in all device models (bar graph, buttons,
LEDs AUT, MAN, ADJ; see chapter 11.1 "Indicator and operating elements"), the INTERBUS model
includes the following additional indicators:
UL RC BA
RD FO1 FO2
UL
= logic voltage U
RC = Remote Bus Check
BA = Bus Activity
RD = Remote Bus Disable
FO1 = Fiber Optics 1
FO2 = Fiber Optics 2
Figure 7.3:Indicator/operating elements for the INTERBUS model
Note!
The DDLS 200 is an INTERBUS subscriber (Ident-Code: 0x0C = 12
scriber description can be downloaded from http://www.leuze.com.
If the value falls below the warning level (bar graph), a peripheral error message is transmit-
ted via the INTERBUS. When this error message is transmitted, the usual cause is soiling
of the glass optics (see chapter 12.1 "Cleaning"), an incorrectly adjusted data transmission
path, or an interrupted light path.
You can also use the diagnostic options available via the INTERBUS.
Leuze electronic
LED UL: green
green flashing = transmitter /receiver unit switched off via
AUT
MAN
ADJ
off
LED RC: green
off
L
LED BA: green
off
LED RD: yellow
off
LED FO1: yellow
off
LED FO2: yellow
off
INTERBUS 2Mbit/s Fiber-Optic Cable
= operating indicator (Power on)
switching input IN or hardware error
= no operating voltage
= INTERBUS connection OK
= INTERBUS in reset mode or connection
not OK
= display of bus activity
= no bus activity
= continuing bus switched off
= continuing bus detected
= initialization faulty or MAU warning (Mas-
ter in RUN state)
= initialization OK, no MAU warning (Master
in READY state)
= initialization faulty or MAU warning (Mas-
ter in RUN state)
= initialization OK, no MAU warning (Master
in READY state)