10.4

Wiring

Note!
As shown in figure 10.5 through figure 10.7, a distinction is to be made between a 1 : 1 cable
and a "crossover" cable. The "crossover" cable is required whenever the participants
(switch, hub, router, PC, PLC, etc.) connected to the DDLS 200 do not provide "autocross-
ing". If the "autocrossing" function is available in the connected participants, a normal 1 : 1
cable can be used.
DDLS 200 between switch/hub and terminal/PLC
Switch / hub
1 : 1 cable
Figure 10.5:DDLS 200 between switch/hub and terminal/PLC
Note!
Make sure that the 1 : 1 cable and crossover cable are connected correctly.
Do not plug the 1 : 1 cable to the switch/hub into the "Uplink" port.
DDLS 200 between switch/hub and switch/hub
Switch / hub
1 : 1 cable
Figure 10.6:DDLS 200 between switch/hub and switch/hub
Note!
Make sure that the 1 : 1 cable and crossover cable are connected correctly.
Do not plug the 1 : 1 cable to the switch/hub into the "Uplink" port.
Leuze electronic
Optical data transmission
Optical data transmission
DDLS 200
Terminal / PLC
Crossover cable
1 : 1 cable
Ethernet
Switch / hub
53