Biosan Bio RS-24 Operating Manual

Biosan Bio RS-24 Operating Manual

Mini-rotator with timer for test tubes
Hide thumbs Also See for Bio RS-24:

Advertisement

Bio RS-24
Mini-Rotator
with timer for test tubes
Operating Manual
Certificate
Medical–Biological
Research & Technologies
for version
V.1AW

Advertisement

loading
Need help?

Need help?

Do you have a question about the Bio RS-24 and is the answer not in the manual?

Questions and answers

Summary of Contents for Biosan Bio RS-24

  • Page 1 Medical–Biological Research & Technologies Bio RS-24 Mini-Rotator with timer for test tubes Operating Manual for version V.1AW Certificate...
  • Page 2: Table Of Contents

    Contents 1. Safety Precautions 2. General Information 3. Getting Started 4. Operation 5. Specifications 6. Maintenance 7. Warranty and Claims 8. Declaration of Conformity Page 2...
  • Page 3: Safety Precautions

    1. Safety precautions The following symbols mean: Caution! Make sure you have fully read and understood the present Manual before using the equipment. Please pay special attention to sections marked by this symbol. GENERAL SAFETY Use only as specified in the operating instructions provided. ·...
  • Page 4: General Information

    Mini-rotator provides vertical rotation of the platform. It is an ideal instrument for preventing blood coagulations, for extraction, diffusion and dialyzing biological liquids in test tubes. Bio RS-24 is a compact device suitable for convenient use in small laboratories. Page 4...
  • Page 5: Getting Started

    Examine the unit carefully for any damage incurred during transit. The warranty does not cover in-transit damage. 3.2. Complete set. Package contents: Standard set Mini-Rotator with timer for test tubes Bio RS-24, with PRS-22 platform u ..............1 piece External power supply unit ..............1 piece Operating Manual;...
  • Page 6: Operation

    4. Operation 4.1. Connect the external power supply unit to the electric circuit. 4.2. Place tubes on the platform: microtubes up to the end; vacutainers and tubes with caps - halfsize. 4.3. Switch On the Power switch (Fig.1/1), timer indication (Fig.1/2) will light up. 4.4.
  • Page 7: Specifications

    **PRS platforms are equipped with universal rubber clamps for different size tube fixation; PRSC platforms have metal clamps able to hold heavier solutions (e.g.soil,sand). Biosan is committed to a continuous programme of improvement and reserves the right to alter design and specifications of the equipment without additional notice.
  • Page 8: Maintenance

    6. Maintenance 6.1. If the unit requires maintenance, disconnect the unit from the mains and contact Biosan or your local Biosan representative. 6.2. All maintenance and repair operations must be performed only by qualified and specially trained personnel. 6.3. Standard ethanol (75%) or other cleaning agents recommended for cleaning of laboratory equipment can be used for cleaning and decontamination of the unit.
  • Page 9: Warranty And Claims

    7.3. If any manufacturing defects are discovered by the Customer, an unsatisfactory equipment claim shall be compiled, certified and sent to the local distributor address. Please visit www.biosan.lv, Technical support section to obtain the claim form. 7.4. The following information will be required in the event that warranty or post- warranty service comes necessary.
  • Page 10: Declaration Of Conformity

    8. Declaration of Conformity Page 10...
  • Page 11 Version 1.04 - February 2013...