Siemens SITRANS TS100 Compact Operating Instructions page 55

Temperature sensors
Table of Contents

Advertisement

See also
Maximum permitted sample temperatures within the process (Page 54)
Resistance thermometers
Table 8- 11
RTD temperature sensor (R
1 x RTD TF/3 mm/6 mm
2 x RTD TF/3 mm/6 mm
1 x RTD WW/3 mm/6 mm
2 x RTD WW/3 mm/6 mm
T1 = 450 °C -10K
T2 = 300 °C -10K
T3 = 200 °C - 5K
T4 = 135 °C - 5K
T6 = 85 °C - 5K
For example SITRANS TH
1)
Thermocouples
Table 8- 12
Thermocouple temperature sensor (R
1 x TC type J, K, N /3 mm
2 x TC type J, K, N /3 mm
1 x TC type J, K, N /6 mm
2 x TC type J, K, N /6 mm
T1 = 450 °C -10K
T2 = 300 °C -10K
T3 = 200 °C -5K
T4 = 135 °C -5K
T6 = 85 °C -5K
TS100/TS200/TS300/TS500/TSinsert/TSthermowell
Compact Operating Instructions, 01/2018, A5E03920348-AE
max=120 K/W)
th
Max. permissible sample temperature (°C)
Certified transmitter in Zone 0 with type of
protection "Intrinsically safe"
P0: 0 ... ≤37 mW
P0: ≥37 ... ≤100 mW
1)
348
228
152
100
60
max=15 K/W)
th
Max. permissible sample temperature (°C)
Certified transmitter in Zone 0 with type of
protection "Intrinsically safe"
P0: 0 ... 100 mW
351
231
155
103
63
Certified transmitter in Zone 1, 2 with type
of protection "Intrinsically safe"
P0: 0 ... ≤37 mW
340
436
220
286
144
191
92
126
52
76
Certified transmitter in Zone 1, 2 with type
of protection "Intrinsically safe"
Technical data
8.1 Rated conditions
P0: ≥37 ... ≤100
1)
mW
428
278
183
118
68
439
289
194
129
79
55

Advertisement