JASON Hydrotherapy RE630PS Owner's Manual
Hide thumbs Also See for RE630PS:

Advertisement

Quick Links

"TO BE REMOVED FOR USE BY THE OCCUPANT."
Jason International, Inc.
8328 MacArthur Drive
North Little Rock, AR 72118
www.jasoninternational.com
MADE IN THE U.S.A.
InsTallaTIOn, OPeraTIOn, anD MaInTenanCe
If the carton shows sign of damage, inspect
the product before accepting and describe the
problem on the Bill of lading.
InsPeCTIOn
Inspect the unit prior to installation. In the event of a
problem, DO NOT install the unit.
All components are factory assembled to the bath and the
unit is water tested and inspected prior to leaving Jason
International, Inc.
If the carton shows sign of damage, inspect the product
before accepting and describe the problem on the Bill of
Lading.
NOTE: Transportation and insurance from Jason's
factory are the buyer's responsibility.
Damage sustained in transit is the responsibility of
the carrier. If damage is discovered, the carrier must
be immediately notified in writing with a request for a
representative to inspect the unit. Failure of the carrier
to respond should be reported to the seller and carrier.
Always file a freight claim promptly.
The installer is responsible for insuring that the unit is
free from defects or shipping damage. In the event of a
problem, DO NOT install the unit.
Owner's reCOrD
Dealer:
Date Purchased:
Date Installed:
Installer:
Jason International, Inc. • 501.771.4477
Owner's Manual
rC/re630Ps & rC553Ps forma ®
soaking, airmasseur ® , & Microsilk ® Baths
Jason International is not responsible for damage that
might have been avoided by inspection or testing prior to
installation.
Damage to the unit during installation will not be covered
by warranty and is the responsibility of the installer.
ALL WARRANTY CLAIMS ON ACRYLIC SURFACE
DAMAGE MUST BE MADE PRIOR TO INSTALLATION.
Inspect plumbing and bath surface for missing or damaged
components. Alert your dealer of any discrepancies.
To protect the unit from damage keep the bath in the
carton until ready for installation.
EQUIPMENT ACCESS
In accordance with Building Codes, service access
to all therapy bath equipment, controls and electrical
connections must be provided during installation
(Recommended minimum 28" x 17" [71 x 43 cm]).
Insufficient access will hinder repair and maintenance.
Warranty service will not cover costs of providing
equipment access.
The Specification Sheet for this bath contains additional
technical information. This sheet can be provided by your
dealer or accessed online at www.jasoninternational.com.
PlaCe serIal nuMBer CarD wITh
PrODuCT COnfIguraTIOn In ThIs BOx
Page 1 of 24
49-1011-004
Date 11/13
Customer Service : 800.255.5766
Copyright © 2013 Jason International.

Advertisement

Table of Contents
loading

Summary of Contents for JASON Hydrotherapy RE630PS

  • Page 1 North Little Rock, AR 72118 www.jasoninternational.com MADE IN THE U.S.A. Owner’s Manual rC/re630Ps & rC553Ps forma ® soaking, airmasseur ® , & Microsilk ® Baths InsTallaTIOn, OPeraTIOn, anD MaInTenanCe If the carton shows sign of damage, inspect Jason International is not responsible for damage that...
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS INSTALLATION For baths with the AEC Equipment Cabinet, set the AEC carton aside to be installed later Remove the product from its packaging. Read the entire 4. Cardboard bath-well protector. Each bath is provided instructions prior to installing this product. with a cardboard bath-well protector that should be kept in See the USER MAINTENANCE INSTRUCTIONS section of the unit throughout the bathroom construction process.
  • Page 3 INSTALLATION INSTRUCTIONS (cont.) 8. After the finished floor is installed, position the installation 12. Dry fit the drain and overflow to the bath. template on the finished floor. Place the template to line up with the existing floor drain location and orient the template Dry fit the drain and overflow to the bath.
  • Page 4 INSTALLATION INSTRUCTIONS (cont.) Figure 5 Figure 6 17. Attach faucet accessories to the bath (if applicable). Place bath and skirt assembly on raised blocks approxi- CAUTION: There is not enough room to mount a deck mately 8" tall. mounted diverter valve on the deck of the bath. 22.
  • Page 5 INSTALLATION INSTRUCTIONS (cont.) 25. Drain and overflow. Complete the installation of the ELECTRICAL drain and overflow per the instructions included with Electrical Power Supply: These instructions are written the drain and overflow. assuming 60Hz, 120v (or 240V for Signature Edition) power Test bath controls.
  • Page 6 INSTALLATION INSTRUCTIONS (cont.) ® ® 4. AirMasseur Equipment Standard/Premier Edition AirMasseur Control Box ® The AirMasseur equipment may be shipped separate- (240v). The blower control box must be plugged into a ly from the bath. The blower is prewired to the control dedicated 240v (volt), 15A (amp), 50Hz (hertz), Ground box.
  • Page 7 INSTALLATION INSTRUCTIONS (cont.) ® 5. MicroSilk Equipment Standard/Premier Edition MicroSilk Control Box The MicroSilk equipment will be shipped separate (240v). The MicroSilk control must be plugged into a from the bath with the AEC Equipment Cabinet. Follow dedicated 240v, 15A, 60Hz, GFCI protected circuit. the instructions for the AEC EQUIPMENT CABINET See Figure 10.
  • Page 8 INSTALLATION INSTRUCTIONS (cont.) REMOTE MOUNTING OF AIR BLOWER 3. Attach hose. Attach one end of the blower hose to the bath connection with the included clamp. ® The Jason AirMasseur system has been factory installed following E.T.L. guidelines. During installation, if remote 4.
  • Page 9 INSTALLATION INSTRUCTIONS (cont.) ACRYLIC EQUIPMENT CABINET INSTALLATION CAUTION: Do not allow the cabinet to touch the bath or the skirt. This could produce excessive noise. The Jason Acrylic Equipment Cabinet (AEC ) can be used to house the bath equipment that cannot be remote The PVC trim, around the opening in the cabinet, has a mounted away from the bath.
  • Page 10 INSTALLATION INSTRUCTIONS (cont.) 5. For MicroSilk baths, clamp the plumbing lines to Figure 13b the appropriate barb using the clamp provided. Assure the line will allow proper drainage to the bath fitting. The hose must have a continuous drop from the barb to the fitting.
  • Page 11: Water Testing

    INSTALLATION INSTRUCTIONS (cont.) CLEANING WATER TESTING 1. Remove all loose debris. Construction plaster or Before finishing the installation, it is recommended that the excess grout can be removed with the use of a wood bath be water tested and the plumbing tested for leaks. (edge) trowel.
  • Page 12 AIRMASSEUR® CONTROL BOX CONNECTIONS ® STANDARD EDITION AIRMASSEUR Figure 15 ® Jason’s Standard Edition AirMasseur system features the best in luxury bathing for the leisure bath industry. To assure that your bath functions properly the blower control must be properly connected. NOTE: For 120v systems, the power cord for the Blower control box must be plugged into a 120v, 15 amp GFCI dedicated circuit.
  • Page 13 CONTROL BOX CONNECTIONS (cont.) ® SIGNATURE EDITION AIRMASSEUR Figure 17 ® Jason’s Signature Edition AirMasseur system is the most advanced bath manufactured by Jason International, Inc. and features the ultimate in luxury bathing for the leisure bath industry. The blower control box must be properly connected for the bath to function correctly.
  • Page 14 CONTROL BOX CONNECTIONS (cont.) ® PREMIER EDITION MICROSILK Figure 19 ® Jason’s Premier Edition MicroSilk system incorporates all the features of the Standard Edition system and includes the benefits of an ozone sanitation system and an LED Chromatherapy light. To assure that your bath functions ®...
  • Page 15: Operation

    OPERATING INSTRUCTIONS, FEATURES, & CONTROLS INTRODUCTION Signature Touchpad A main control touchpad mounted on the bath deck features This manual contains all of the information needed for a LCD readout which alternately indicates the water tem- the proper installation and operation of your Jason bath. perature (+/- 5°F) and time remaining.
  • Page 16 OPERATING INSTRUCTIONS, FEATURES, ANd CONTROLS (cont.) STANDARD EDITION AIRMASSEUR ® TOUCHPAD ® The Jason Standard Edition AirMasseur touchpad is used to access all the functions of the blower control. Mode Blower Speeds Option AirMasseur OPERATING INSTRUCTIONS Blower Speeds Icon The Blower Speeds icon is used to increase or decrease ®...
  • Page 17 OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.) SIGNATURE EDITION AIRMASSEUR ® TOUCHPAD The Jason Signature Edition Digital AirMasseur touchpad is used to access all ® of the functions of the control box used in a Jason Signature Edition AirMasseur bath. ® Figure 9 Blower On/Off, Modes Blower Speeds...
  • Page 18 OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.) MICROSILK ® OPERATION Signature Remote Control In addition to the main control touchpad installed on the ® STANDARD AND PREMIER EDITION MICROSILK bath deck, a floating, waterproof Universal Remote Control ® is provided with all Signature Edition MicroSilk baths.
  • Page 19 OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.) STANDARD AND PREMIER EDITION ® MICROSILK TOUCHPAD MICROSILK ® ® LED Light MicroSilk™ On/Off The Jason Standard and Premier Edition MicroSilk ® LED Light Icon touchpad is used to access all of the functions of the pump The LED Light icon is used to operate an LED light (if control.
  • Page 20 OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.) SIGNATURE EDITION ® MICROSILK TOUCHPAD For Diagnostic Functions For Diagnostic Functions ® LED Light MicroSilk™ On/Off IR for Remote Display Panel ® The Jason Signature Edition MicroSilk digital touchpad is Menu Instructions ® used to access all the functions of the MicroSilk bath.
  • Page 21: User Maintenance Instructions

    USER MAINTENANCE INSTRUCTIONS HUMIDITY SURFACE MAINTENANCE Areas with minor scratches or dull surfaces can be WARNING: AVOID HIGH HUMIDITY LEVELS IN YOUR restored by applying commercially available plastic polish HOME. MOLD, MILDEW, FUNGI AND BACTERIA (i.e. Novus Plastic Polish No. 2, available at your Jason WHICH MAY BE HARMFUL TO HEALTH THRIVE dealer), followed by an application of acrylic paste wax.
  • Page 22: Troubleshooting Guide

    TROUBLE SHOOTING GUIdE If you believe the unit to be within the warranty period, you must contact Jason Customer Service: 1-800-255-5766 with the bath’s Product and Serial numbers before work is started. ALL WARRANTY REPAIRS MUST BE AUTHORIZED BY JASON BEFORE WORK IS STARTED. FOR SERVICE, ALWAYS CONTACT YOUR DEALER OR AUTHORIZED SERVICE CENTER ®...
  • Page 23 MICrOsIlK PuMP sysTeM ® syMPTOMs POssIBle Causes reCOMMenDeD aCTIOn MicroSilk system fails No power to the MicroSilk unit. Reset circuit breakers and GFCI if tripped. Check fuses to operate. Motor is not plugged in. and replace if bad. Touch Control — insufficient water Check voltage at motor when control is on.
  • Page 24: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS InsTruCTIOns PerTaInIng TO The rIsK Of fIre, eleCTrIC shOCK, Or InJury TO PersOns. This manual contains information and instructions for proper operation and maintenance of your therapy bath. Failure to follow these instructions could result in personal injury, electrical shock, or fire. warnIng: when using this unit, basic precautions should always be followed, including the following: reaD anD fOllOw all InsTruCTIOns Carefully Danger:...

This manual is also suitable for:

Rc630psRc553ps

Table of Contents