Example: Digital Output Configuration (Basic); Example: Matrix Switching (Basic) - Keysight E1463A User Manual

32-channel 5-amp form c switch
Hide thumbs Also See for E1463A:
Table of Contents

Advertisement

Using the Form C Switch

Example: Digital Output Configuration (BASIC)

Figure 2-3 shows channel 00 configured for digital output operation.
When the channel 00 relay is open (NC connected to C), point 1 is at +V
and point 2 is at 0V. When the channel 00 relay is closed (NO connected
to C), points 1 and 2 are both at 0V. To close channel 00, execute the following.
To open channel 00, use OPEN (@100).
10 DISP "Closing channel 0"
20 OUTPUT 70915; "CLOS (@100)" !Close channel 00 relay (connect NO to
30
Figure 2-3 Example: Digital Output Configuration

Example: Matrix Switching (BASIC)

The Form C switch module can be configured as a 4 x 8 single-wire matrix to
connect any combination of up to four user sources (S0, S1, S2, S3) to any
combination of up to eight user instruments (I0, I1, I1...I7) at a time.
To do this, make the connections shown in Table 2-3.
44
C). 1 is the card number and 00 is the channel number.
END
E1463A
MODULE
Channel
C
TERMINAL
MODULE
00
C0NO
NO
C0NC
NC
C0C
Relay
1
2
Open
+V
0V
Closed
OV
OV
Keysight E1463A 32-Channel Form C Switch User Guide
Switching Channels
+V
1
2

Advertisement

Table of Contents
loading

Table of Contents