Keysight 8710 Series Operating And Service Manual
Keysight 8710 Series Operating And Service Manual

Keysight 8710 Series Operating And Service Manual

Low pim coxial multiport switches
Hide thumbs Also See for 8710 Series:

Advertisement

Quick Links

Keysight 8710x Low PIM
Coxial Multiport Switches
Operating and
Service Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8710 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Keysight 8710 Series

  • Page 1 Keysight 8710x Low PIM Coxial Multiport Switches Operating and Service Manual...
  • Page 2 Declarations of Conformity for this product ceed beyond a CAUTION notice until the indi- DFARS and are set forth specifically in writing and for other Keysight products may be down- cated conditions are fully understood and met. elsewhere in the EULA. Keysight shall be loaded from the Web.
  • Page 3: Waste Electrical And Electronic Equipment (Weee) Directive

    To return this unwanted instrument, contact your nearest Keysight Service Center, or visit http:// about.keysight.com/en/companyinfo/environment/takeback.shtml for more information. Sales and Technical Support To contact Keysight for sales and technical support, refer to the support links on the following Keysight websites: – www.keysight.com/find/switches (product-specific information and support, software and documentation updates) –...
  • Page 4 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight 8710x Operating and Service Manual...
  • Page 5: Table Of Contents

    ..........32 Keysight 8710x Operating and Service Manual...
  • Page 6 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight 8710x Operating and Service Manual...
  • Page 7: List Of Figures

    ..... . . 26 Figure 3-4 Dimensions of Keysight 8710x low PIM coaxial multiport switches . . 28 Figure 4-1 Connection to perform quick check .
  • Page 8 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight 8710x Operating and Service Manual...
  • Page 9: List Of Tables

    List of Tables Table 1-1 List of Keysight 8710x low PIM coaxial multiport switches ..12 Table 3-1 General specifications ........22...
  • Page 10 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight 8710x Operating and Service Manual...
  • Page 11 Keysight 8710x Low PIM Coxial Multiport Switches Operating and Service Manual Introduction General Information Key Features This chapter provides you the overview of Keysight 8710x low PIM coaxial multiport switches.
  • Page 12: Introduction

    Introduction General Information Keysight 87104P/Q/R SP4T and 87106P/Q/R SP6T terminated switches provide the life and reliability required for automated test and measurement and signal monitoring and routing applications. These switches can be used in various applications as they are available in multiple frequency ranges, up to 26.5 GHz.
  • Page 13: Key Features

    – Guaranteed repeatability of 0.03 dB up to 3 million cycles, ensuring accurate system measurements and reducing calibration intervals – Excellent isolation, typically > 90 dB at 26.5 GHz – PIM level (typical) of –165 dBc – Opto-electronic indicators and interrupts – Terminated ports Keysight 8710x Operating and Service Manual...
  • Page 14 Introduction THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight 8710x Operating and Service Manual...
  • Page 15 TTL Drive (Option T24) Electronic Position Indicators This chapter provides you information on how to drive the switches using standard drive and TTL drive. Also included is the configuration to utilize the function of the position indicator. Keysight 8710x Operating and Service Manual...
  • Page 16: Switch Configuration

    RF path is closed (15 ms), de-select the old RF path “drive” pin while leaving the new RF path “drive” pin selected. The switch circuitry will automatically open the old RF path while leaving the new RF path engaged. Keysight 8710x Operating and Service Manual...
  • Page 17: Standard Drive

    RF path. 4 To open all RF paths, ensure that all RF path “drive” pins are disconnected from ground. Then, connect pin 16 to ground. This feature is not available in option 100. Keysight 8710x Operating and Service Manual...
  • Page 18: Ttl Drive (Option T24)

    RF path. 4 To open all RF paths, ensure that all RF path “drive” pins are at TTL “Low”. Then, apply TTL “High” to pin. This feature is not available in option 100. Keysight 8710x Operating and Service Manual...
  • Page 19: Electronic Position Indicators

    (20 to 32 VDC) be connected to pin 1 and ground connected to pin 15. *Paths 1 and 4 are not connected for 87104P/Q/R Figure 2-2 Pin configuration for indicator function Keysight 8710x Operating and Service Manual...
  • Page 20 Switch Configuration THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight 8710x Operating and Service Manual...
  • Page 21: General Specifications

    Specifications refer to the performance standards or limits against which the coaxial multiport switches are tested. Typical characteristics are included for additional information only and they are not specifications. These are denoted as “typical”, “nominal”, or “approximate” and are printed in italics. Keysight 8710x Operating and Service Manual...
  • Page 22: Specifications

    – Ambient temperature of 75 °C or less – Sea level (0.88 derating at 15,000 feet) – Low VSWR < 1.2 (See Figure 3-2 for derating above 1.2 VSWR) Figure 3-1 Maximum incident power (cold switching) vs. frequency Keysight 8710x Operating and Service Manual...
  • Page 23: Figure 3-2 Power Derating Factor Vs. Vswr

    Specifications Figure 3-2 Power derating factor vs. VSWR Keysight 8710x Operating and Service Manual...
  • Page 24: Rf Specifications

    < 1.45 (12.4 to 20 GHz) < 1.70 (20 to 26.5 GHz) < 0.03 Repeatability (dB) Characteristics 50 Ω, terminated Connectors SMA (f) [a] f = frequency in GHz [b] Up to 3 million cycles, measured at 25 °C Keysight 8710x Operating and Service Manual...
  • Page 25: Indicator Specifications

    Specifications Indicator Specifications Table 3-4 Indicator specifications Keysight model number 87104P/Q/R and 87106P/Q/R Maximum withstand voltage 60 V Maximum current capacity 150 mA Maximum “ON” resistance 2.5 Ω Maximum “OFF” resistance 10 GΩ Keysight 8710x Operating and Service Manual...
  • Page 26: Switch Drive Specifications

    Switch drive specifications for TTL drive (option 24) Parameter Unit High level input Low level input Max high input current [a] Vcc = Max. Vinput = 3.85 VDC. Figure 3-3 TTL control voltage states (Option T24) Keysight 8710x Operating and Service Manual...
  • Page 27: Environmental Specifications

    Specifications Environmental Specifications The N1923/4A low PIM coaxial multiport switches are designed to fully comply with Keysight’s product operating environmental specifications. Table 3-7 Environmental specifications Parameter Specification Temperature – Operating –25 °C to 75 °C – Storage –55 °C to 85 °C –...
  • Page 28: Physical Specifications

    Specifications Physical Specifications Table 3-8 Physical specifications Parameter Specification Dimensions Figure 3-4 Net weight, kg (lb) 0.370 (0.82) Figure 3-4 Dimensions of Keysight 8710x low PIM coaxial multiport switches Keysight 8710x Operating and Service Manual...
  • Page 29 Keysight 8710x Low PIM Coxial Multiport Switches Operating and Service Manual Installation and Verification Installation Operating and Service Instructions This chapter provides you installation information and simple verification steps of the switches.
  • Page 30: Installation And Verification

    Refer to “Sales and Technical Support” on page 3 for the Keysight office nearest to you. Attach a tag indicating the type of service required, return address, model number, and serial number. Mark the container FRAGILE to insure careful handling.
  • Page 31: Operating And Service Instructions

    The network analyzer may be set to sweep over the whole or selected frequency range of the switch to be verified. The S-parameter measurement is the best way to determine if the switch is working properly. Figure 4-1 Connection to perform quick check Keysight 8710x Operating and Service Manual...
  • Page 32: Performance Test

    33 for more details. Maintenance The connectors, particularly the connector faces, must be kept clean. For instructions on connecting and care of your connectors, refer to the Microwave Connector Care Quick Reference Card (08510-90360). Keysight 8710x Operating and Service Manual...
  • Page 33: Replacement Units

    Low PIM switch, SP6T, DC - 26.5 GHz, terminated with Option 161, T24 87106-60105 The above list of replacement units is not applicable as customer-orderable units. The list only NOTE applies for any low PIM coaxial multiport switch which fails within the warranty period. Keysight 8710x Operating and Service Manual...
  • Page 34 Installation and Verification THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight 8710x Operating and Service Manual...
  • Page 35 This information is subject to change without notice. Always refer to the Keysight website for the latest revision. © Keysight Technologies 2014 - 2019 Edition 3, March 14, 2019 Printed in Malaysia *87104-80017* 87104-80017 www.keysight.com...

This manual is also suitable for:

87104q87106p87106r87104r87106q87104p

Table of Contents