Sign In
Upload
Manuals
Brands
Keysight Manuals
Switch
34980A
Keysight 34980A Manuals
Manuals and User Guides for Keysight 34980A. We have
2
Keysight 34980A manuals available for free PDF download: User Manual, Getting Started Manual
Keysight 34980A User Manual (227 pages)
Multifunction Switch/ Measure Unit
Brand:
Keysight
| Category:
Switch
| Size: 3 MB
Table of Contents
Safety Symbols
3
General
4
Before Applying Power
4
Ground the Instrument
4
Do Not Operate in an Explosive Atmosphere
4
Do Not Remove the Instrument Cover
5
Do Not Modify the Instrument
5
In Case of Damage
5
Environmental Conditions
5
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC
6
Product Category
6
Sales and Technical Support
6
Table of Contents
7
Additional Safety Notices
4
1 Introduction to the 34980A
14
Data Acquisition Overview
14
Measurement Software
15
Data Acquisition Circuitry
17
Plug-In Modules
19
System Cabling
19
Transducers and Sensors
20
Alarm Limits
21
Signal Routing and Switching
22
Switching Topologies
22
RF and Microwave Switching
24
Measurement Input
25
The Internal DMM
25
Scanning
27
Scanning with External Instruments
29
The Digital Modules
31
Control Output
33
The Digital Modules
33
The Actuator / General-Purpose Switches
35
2 Getting Started
38
Front Panel at a Glance
38
Rear Panel at a Glance
40
Rear Panel Connector Pinouts
42
External Trigger/Alarms Connector (Male D-Sub)
42
Analog Bus Connector (Female D-Sub)
43
Annunciator Display Indicators
44
Installing and Connecting Modules
46
Removing a Slot Cover
46
Installing a Module
47
Instrument Rack Mounting
55
Operating the 34980A from the Front Panel Keyboard
58
Front Panel Menu Reference
58
Menu Example 1: Setting the Time and Date
61
Menu Example 2: Opening and Closing Channel Relays
63
Using the Measure Keys
65
Menu Example 3: Configuring the DMM for a Measurement
66
Menu Example 4: Configuring a Channel for a Measurement
69
Connecting the 34980A to Your Computer
73
Connecting over LAN
74
Connecting over GPIB
80
Connecting over USB
81
Communicating with the 34980A
83
Operating the 34980A Using the Integrated Web Browser Interface
84
Launching the Web Interface
85
Displaying the Browser Web Control Page
87
Selecting the "Allow Full Control" Mode
88
Setting a Web Browser Password
89
Closing and Opening Channel Relays
90
Modifying the Channel Configuration
91
Sending SCPI Commands Via the Web Interface
92
34980A Documentation Map
95
Front Panel Features
99
Front Panel Display
99
Front Panel Controls
101
Basic Operating Modes
102
SCPI Commands
103
SCPI Language Conventions
103
Rules for Using a Channel List
104
Remote Interface Configuration
105
GPIB Interface
106
LAN Interface
106
Clearing 34980A Memory
115
Volatile Memory
115
Non-Volatile Memory
115
Analog Bus and Internal DMM Considerations
117
Environmental Operating Conditions
117
Electrical Operating Conditions
118
General Measurement Configuration
119
Overview of Measurement Modes
119
Analog Buses
122
Measurement Functions
123
Measurement Range
124
Measurement Resolution
125
Custom A/D Integration Time
127
Autozero
128
Trigger Delay
129
Automatic Trigger Delays
130
Safety Interlock
131
User-Defined Channel Labels
132
2-Wire Versus 1-Wire Mode
134
3 Features and Functions
99
Temperature Measurement Configuration
135
Measurement Units
135
Thermocouple Measurements
136
RTD Measurements
138
Thermistor Measurements
139
Voltage Measurement Configuration
140
DC Input Resistance
140
AC Low Frequency Filter
141
Resistance Measurement Configuration
142
Offset Compensation
142
Current Measurement Configuration
143
AC Low Frequency Filter
143
Frequency Measurement Configuration
145
Low Frequency Timeout
145
MX+B Scaling
146
Scanning
148
Rules for Scanning
148
Adding Channels to the Scan List
150
Scan Trigger Source
152
Trigger Count
157
Sweep Count
158
Sample Count
159
Channel Delay
161
Automatic Channel Delays
163
Reading Format
164
Non-Sequential Scanning
166
Viewing Readings Stored in Memory
167
Monitor Mode
169
Scanning with External Instruments
171
Alarm Limits
174
Viewing Stored Alarm Data
178
Using the Alarm Output Lines
179
Using Alarms with the Digital Modules
181
Sequences
184
Defining a Sequence
185
Querying the Sequence Definition
187
Executing a Sequence
187
Executing a Sequence on an Alarm Condition
188
Deleting Sequences
190
Reading the List of Stored Sequences
190
System-Related Operations
191
Firmware Revision
191
Product Firmware Updates
192
Instrument State Storage
192
Error Conditions
194
Self-Test
195
Front-Panel Display Control
196
Front-Panel Number Format
197
Real-Time System Clock
197
Internal DMM Disable
198
Relay Cycle Count
198
SCPI Language Version
199
Calibration Overview
200
Calibration Security
200
Calibration Count
201
Calibration Message
202
Factory Reset State
203
Instrument Preset State
206
4 Introduction to the Plug-In Modules for the 34980A
210
User's Guides for the 34980A's Plug-In Modules
210
Available Modules, at a Glance
211
Slot and Channel Addressing Scheme
213
Interconnection Solutions Overview
215
Module Considerations
217
General Considerations
217
Environmental Operating Conditions
217
Electrical Operating Conditions
219
Advertisement
Keysight 34980A Getting Started Manual (67 pages)
Multifunction Switch/Measure Unit
Brand:
Keysight
| Category:
Switch
| Size: 2 MB
Table of Contents
Safety Symbols
3
Additional Safety Notices
4
Environmental Conditions
8
Regulatory Markings
9
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/ EC
11
Sales and Technical Support
11
Table of Contents
13
Getting Started
16
Contents of Your Shipment
16
Front Panel at a Glance
17
Rear Panel at a Glance
19
Removing a Slot Cover
21
Installing a Module
23
Installing a Module for Use with Cables
23
Installing a Module for Use with Terminal Blocks
24
Wiring and Installing a Terminal Block
26
Wiring a Terminal Block
26
Installing a Terminal Block
31
Operating the Front Panel Keyboard
34
Menu Example: Selecting a Channel and Operating the Channel Relay
34
Menu Example: Setting the Time and Date
35
Using the Measure Keys
37
Menu Example: Configuring the Internal DMM for a Measurement
38
Menu Example: Configuring a Channel for a Measurement
40
Connecting the 34980A to Your Computer
46
Connecting over LAN
46
Connecting over GPIB
51
Connecting over USB
53
Communicating with the 34980A
54
Exploring the 34980A Web Interface over LAN
55
34980A Documentation Map
66
Advertisement
Related Products
Keysight 34970A
Keysight 34972A
Keysight 34907A
Keysight 34924A
Keysight 34925A
Keysight 34923A
Keysight 34951A
Keysight 34934A
Keysight 34959A
Keysight 34922A
Keysight Categories
Measuring Instruments
Test Equipment
Multimeter
Portable Generator
Power Supply
More Keysight Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL