Figure A-32 Putting a coaxial cable into a sleeve
Step 3 Expand outer conductor D of the coaxial cable into a bell-mouthed shape as shown in
A-33.
Figure A-33 Expanding the outer conductor of a coaxial cable
Step 4 Insert the inner conductor and insulation part of the coaxial cable into plug B of the connector.
Wrap outer conductor D of the connector by using the outer conductor of the coaxial cable, as
shown in
Figure A-34 Inserting a coaxial cable into a connector plug
Issue 01 (2012-07-25)
A
D
Figure
A-34.
D
B