SmartAX MA5612 Multi-service Access Module
Maintenance Guide
After the OT terminal is installed, the length of the bare conductor outside the bare crimping
terminal (L2) must not be more than 2 mm. If the length (L2) of the bare conductor outside the
bare crimping OT terminal is larger than 2 mm, cut the redundant part by using the diagonal
pliers or wire clipper, as shown in
Step 4 Use the crimping tool to clamp the tail of the bare crimping terminal and the contact part of the
conductor, as shown in
Figure A-8 Clamping the tail of the bare crimping terminal with the contact part of the conductor
Step 5 Push the heat shrink tubing A towards the connector, and cover the crimping area of the bare
crimping terminal and the conductor. Use a hot air gun to heat the heat shrink tubing, as shown
in
Figure
Do not heat the heat shrink tubing for a long time. Otherwise, the insulation layer may be
damaged.
Issue 01 (2012-07-25)
CAUTION
Figure
B
NOTE
The crimped shapes vary with the crimping molds.
A-9.
CAUTION
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Figure
A-7.
A-8.
A Appendix
274