Hood Operation - GILES OVH-10 Operation & Service Manual

Table of Contents

Advertisement

Operation & Filter Maintenance
4.
Operation & Filter Maintenance
This section explains Ventless Hood operation, required filter maintenance and cleaning, and alarm conditions.
4.01

Hood Operation

Before attempting to operate the Hood, be certain that all Filters are in place and properly installed.
1. Starting the Hood requires that the top [START] portion of the Power Switch
held. When Hood blower starts release switch; it springs back and remains in the [ON] position (center). The
Hood Power
light will turn ON. The E.A.C. [ON] light
or 2 seconds, then the [APPLIANCE POWERED] Light
the Hood is powered and ready to use. The Hood must be restarted in this manner after any power
interruption.
OVH-10
4.02
Filter, Filter Maintenance & Filter Alarms
4.02.1
Ventless Hood Filter Table
Filter
Baffle Filter
EAC Filter Cell
Replace every 30 to 40
Charcoal Filter
4
3
1
2
When to
Clean/Replace
Clean daily
Clean daily
days,
P/N 30248 [PO-VH]
P/N 31963 [OVH-10]
will turn ON and, an alarm tone may sound for 1
should turn ON, indicating that the appliance under
4
2
POVH
How to Remove
Section 4.02.3.1
Section 4.02.5.1
Section 4.02.3.2
Section 4.02.5.2
NEVER attempt to
clean. ONLY Replace
Section 4.02.3.3
Section 4.02.5.3
OVH-10 / PO-VH
be pressed and momentarily
3
How to Clean
How to Install
Section 4.02.3.1
Section 4.02.3.2
Section 4.02.3.3
1