Safety Precautions - Animo ComBi-line Series User Manual

Table of Contents

Advertisement

ComBi-line
1.5.4
Swivel arm protection for wall mounted CB and CB W models
The wall mounted CB and CB W models have an adjustable stop at the bottom of the swivel arm. The
stop prevents the starting of a brewing process when the swivel arm is not in the correct pre-set
position.
1.5.5
Boiler system steam outlet for CB W models
All CB W models have a steam outlet at the top of the tower. The steam outlet lets excess steam
escape from the boiler system. Do not touch the boiler steam outlet while the machine is switched on.
The boiler steam outlet is hot.
1.5.6
Temperature safety device in the coffee brew system
A temperature safety device in the coffee brew system turns off the heating element if the temperature
of the system is too high.
1.5.7
Temperature safety device in the boiler system
A temperature safety device in the boiler system turns off each the heating element if the temperature of
the system is too high.
1.5.8
Current overload switch
A current overload switch isolates the mains power supply to the machine if there is a current overload.
1.5.9
Display
A
The display (A) shows technical malfunctions with error codes. The display also provides additional
user information or warnings.
1.6

Safety precautions

1.6.1
General safety precautions
Make sure that the environment around the machine is dry, clean and lit sufficiently well.
Only persons that have specific knowledge and practical experience with the machine, particularly
in regard to safety and hygiene, should be permitted into the service area where the beverage(s)
are prepared.
Keep away from moving parts.
2018/07 Rev 3.0
8
EN

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ComBi-line Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Cb 1x lCb 2xCbCb 1x w lCb wCb 1x w r ... Show all

Table of Contents

Save PDF