Status memory
• In the menu Status memory the last 9 actions of the
control unit can be retrieved with the time stored.
1
CHANGE WATER
2
DESCALE
3
FLUSH
4
UV_CHECK
5
STANDBY
6
CALIBRATE UV
7
CALIBRATE AIR
8
START
9
START USER
0
STANDART
AutoStby active
• The automatic deactivation of the humidification unit
is deactivated with AutoStby active "Off". In
addition, number is now shown in the expert menu
under "AutoStby active "On-Off" the bottom on the
left, which shows the reason for the AutoStby
operation:
1 – No ventilation for 18 hours
2 – EEPROM
3 – Valve openings
4 – Switch
5 – Rinsing
Ext.Temp.Offset
• The external temperature sensor can be calibrated
here.
Language
• The menu guidance can be switched over from
German to English or to French and vice versa in the
menu option Language.
Max. air hum. 80%
• If the parameter "Max. air humidity" is set to "On",
the air humidity setting in the customer´s menu is
expanded by the values 70 % an d 80 %.
AutoStby active On
4
Off<
Ext.Temp.Offset
+0.0
English
German<
Max. air hum. On
Off<
This parameter must not be activated in an
air duct system, if it is integrated into the
humidification unit.
(condensation water may form in the piping
system!)
Rel. air humidity
• In the menu "Relative air humidity" the humidity
control is switched from the absolute air humidity
control at 21 °C to the relative air humidity control.
This parameter must not be activated in an
air duct system, if it is integrated into the
humidification unit.
(condensation water may form in the piping
system!)
Temp.abs.humidity
• Here the temperature is set, to which the absolute
humidity control is related. The value can be set
between 20°C and 24°C in 1-degree increments. This
enables the adjustment of the humidity control to the
room temperature.
Ext. Off
• When the parameter "external Off" is activated to
"On" and if the contact is open at the external
switching input, the device is switched to the
operating status "Control Off"
(For more details, see section 8.4/page 9)
Air flow monitoring via the integrated microphone will
still remain active.
Software type
• Displays the parameterized device type. This setting
can only be adjusted in the factory defaults menu
item.
Rel. air hum.
On
Off<
Temp.abs. humidity
21 °C<
Ext. Off
On
Off<
250
<
500
16