Operating Statuses; Automatic Activation/Deactivation Autumn/Spring (Auto Standby); Manual Activation/Deactivation (Auto Standby); Manual Activation/Deactivation (Manu Standby) - Helios HygroBox KWL Series Installation And Operating Instructions Manual

Hide thumbs Also See for HygroBox KWL Series:
Table of Contents

Advertisement

Available languages

Available languages

Info
<
• The installed software version is shown under Info
Delete fault
<
• Error messages, which appear in the Info line
of the display, are deleted using the Delete Fault Yes<
function.
Expert
<
• With Expert, you can access the next lower
menu level by entering a code. This parameter
can be opened only by the respective expert

8 Operating statuses

Automatic activation/deactivation
8.1
Autumn/Spring (auto STANDBY)
• The humidification unit switches on when the air
humidity is too low (Autumn) and off when the air
humidity is too high (Spring). The following appears
on the display
auto STANDBY
• If the evaporative power within 24 hours is less
than one litre, the device switches off (Auto STANDBY).
• If the humidity undershoots the set humidity by 7%
for a period of 24 hours, the humidification unit
switches on again.
CONTROL ON
Manual activation/deactivation (auto
8.2
STANDBY)
• If the On/Off button is pressed, the following appears on
the display
auto STANDBY
• The humidification unit is switched off and set to the
auto Standby mode.
• If the air humidity falls by 7% under the set value for a
period of 24 hours, the humidification unit switches
on again.
Manual activation/deactivation
8.3
(manu STANDBY)
• If the On/Off button on the key pad is pressed for
longer than 3 seconds, the following appears on the
display
manu STANDBY
• In this operational status, the humidification unit
remains switched off. The water is drained and the
UVC pipe and the rotor are switched off with a delay of
40 minutes.
The humidification unit must be switched on again by
hand. To do so, press the On/Off button.
Software version
V 1.0
01.09.08
Delete
Yes<
fault?
No
Code?
------
.
.
.
Automatic activation/deactivation
8.4
depending on air current ("Control
Off")
• The humidification is controlled automatically by
the operation of the ventilation device. In the
process, an acoustic signal indicates whether the
ventilation system is running.
• Depending on this signal, the humidification unit
switches on and off automatically.
CONTROL ON
• If the ventilation and air conditioning system is shut
down for longer than 18 hours, the humidification
unit switches off automatically.
.
auto STANDBY
• During the operation of the ventilation system, it
switches on automatically again.
Spülen
RINSING
8.5
• The water inlet pipe and the reverse osmosis
membrane are protected against contamination by
the rinsing programme.
• The rinsing programme is performed automatically once
a day while the humidification unit is shut down.
• "RINSING" is shown in the display.
• The rinsing period amounts to 10 minutes and can
be cancelled by pressing the "Back" button.

Regelung ein

CONTROL ON
8.6
• This parameter indicates that the humidity and air
temperature controls are active.
Füllen
FILLING
8.7
• This parameter indicates that the tank is being filled
with water.

Wasserwechsel

WAT. REP.
8.8
• The water in the tank is replaced one to four times a
day for the KWL HB 250 (corresponds to 1 to 10 litres)
or twice a day for the KWL HB 500 (corresponds to 2 to
30 litres of water per day). The following appears in the
display: WAT.REP.
/
CONTROL OFF