Valor BR517R Owner's Manual

Ultimate turbochim* & superflame rf* rear & side fan flued inset
Hide thumbs Also See for BR517R:

Advertisement

O
W
N
E
R
G
M O D E L S
B R 5 1 7 R & B R 5 1 7 S
( G . C . 3 2 - 0 3 2 - 1 1 & 3 2 - 0 3 2 - 1 2 )
& U L T I M A T E T U R B O C H I M *
S U P E R F L A M E R F *
R e a r & S i d e F a n F l u e d
I n s e t G a s F i r e s
*Covered by GB Patent 2.202.622.B
This Owner Guide is intended to help you care for your Valor gas fire.
Please read carefully before using your gas fire and keep for future reference.
This Owner Guide gives sufficient details to enable your gas fire to be operated and
Please keep your Owner Guide in a safe place together with the
U
I
D
&
maintained.
IMPORTANT.
Installer Guide.
E
600B209/01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BR517R and is the answer not in the manual?

Questions and answers

Summary of Contents for Valor BR517R

  • Page 1 I n s e t G a s F i r e s *Covered by GB Patent 2.202.622.B This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using your gas fire and keep for future reference.
  • Page 2: Customer Care

    This appliance is for use in the United Kingdom (GB) and the Republic of Ireland (IE) only. Thank you for choosing Valor. All Valor gas fires are designed to meet the most stringent quality, performance and safety requirements to provide our customers with many years’ trouble-free service.
  • Page 3 At times of very windy weather or low voltage during peak • Contact the Valor AdviceLine on 0345 626 341 with any electricity demand, a slight click may be heard. This is caused by enquiries you may have (local call rates apply in the United the fan control switching between its boost and normal speeds.
  • Page 4 Figure 3 Lighting with a taper the fire repeatedly goes out, have the fire serviced. HOW TO TURN OFF YOUR VALOR GAS FIRE • To turn off the main burner but leave the pilot alight slightly depress the control knob and turn to “PILOT/IGN”.
  • Page 5: Gas Consumption

    PART 3: MAINTENANCE LEANING YOUR ALOR GAS FIRE To maintain the high performance and quality finish of your Valor fire, please follow these guidelines: • Before attempting to clean the fire, please remember to turn off the gas at the fire and the electricity at the isolating switch.
  • Page 6 If the fuel bed components are dislodged or removed, they must be refitted as follows: Only the fuel bed parts supplied with this appliance or authorised Valor replacements must be used. Never add extra coals above the number stated in these instructions.
  • Page 7 We recommend that all gas appliances, wherever situated, are checked annually by a competent person (In the UK, a CORGI registered installer). • If you require your fire to be serviced, please contact Valor Service on 0121 386 6203 and quote the following details; a) - model name b) - model no.
  • Page 8: Useful Telephone Numbers

    Type of fire. c) Model/Name. d) Serial Number. e) The fault, problem or request. General advice about gas and your gas fire: VALOR ADVICELINE 0345 626341. To report faults or arrange for your fire to be serviced: VALOR SERVICE 0121 386 6203.
  • Page 9 BS EN ISO 9001 quality system accepted by the British Standards Institute. The Highest Standards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety, quality and performance. Careful Installation Valor is a Corgi registered company.

This manual is also suitable for:

Br517s

Table of Contents