What to Use
cRIO-9066
Screwdriver, Phillips #2
NI panel mounting kit, 782863-01
Panel mounting plate
M5 or number 10 screw (x4)
What to Do
Complete the following steps to mount the cRIO-9066 on a panel.
1.
Align the cRIO-9066 and the panel mounting plate.
2.
Fasten the panel mounting plate to the cRIO-9066 using the screwdriver and M5 or
number 10 screws. NI provides these screws with the panel mounting kit. Tighten the
screws to a maximum torque of 1.3 N · m (11.5 lb · in.).
Note
because they are the correct depth and thread for the panel mounting plate.
3.
Fasten the panel mounting plate to the surface using the screwdriver and screws that are
appropriate for the surface. The maximum screw size is M5 or number 10.
Panel Mounting Dimensions
The following figure shows the panel mounting dimensions for the cRIO-9066.
You must use the screws provided with the NI panel mounting kit