PROMPTS
Cell Flt Time
14
(60 mins)
NOTE: Refer to table above for
correct default values.
NOTES:
 Changing the IP and Cell comm. path choice defaults the value according to the table in prompt 5.
The control is notified of the failure after the Cell and/or IP fault times expire.
Use DHCP Y/N
15
(Y)_
NIC IP Address:
16
255.255.255.255_
Subnet Mask:
17
255.255.255.255_
Gateway IP Addr:
18
255.255.255.255_
DNS Serv IP Addr:
19
255.255.255.255_
Review? Y/N
20
OPTIONS
This prompt appears only if comm. path includes IP&Cell or Cell.
[00-60]
Enter the time delay (1 – 60) in minutes before the communicator
notifies the control panel that there is a communication path failure to
AlarmNet over the hard-wired Ethernet connection. If the panel has an
alternate communication path, a primary path loss message is sent to
the central station.
[Y], [N]
Dynamically allocates the IP addresses (recommended).
If [N], uses fixed IP addresses.
12 digit:
Enter the 4-part address for this device. The 4 parts of the address
xxx.xxx.xxx.xxx
must be separated by spaces (displayed as periods in Review mode).
12 digit:
Enter the 32-bit address mask used to indicate the portion (bits) of the
xxx.xxx.xxx.xxx
IP address that is being used for the subnet address. The 4 parts of
the address must be separated by spaces (displayed as periods in
Review mode).
12 digit:
Enter the 4-part address assigned to the Gateway. The 4 parts of the
xxx.xxx.xxx.xxx
address must be separated by spaces (displayed as periods in Review
mode).
12 digit:
Enter the 4-part IP address assigned to the DNS (Domain Name
xxx.xxx.xxx.xxx
System) server. The 4 parts of the address must be separated by
spaces (displayed as periods in Review mode).
Reviewing Programming Mode Entries
[Y] = review
To review the programming options (to ensure that the correct entries
[N] = exit
have been made), press [Y]. The programming prompts are displayed
again. Use the up/down arrow keys to scroll through the program
fields without changing any of the values. If a value requires change,
simply type in the correct value.
When the last field is displayed, the "REVIEW?" prompt again
appears.
To exit the programming mode, press [N] in response to the
"REVIEW?" prompt, and refer to Exiting Programming Mode at the
end of this section.