Salicru ADAPT Series User Manual

Salicru ADAPT Series User Manual

10-200kva

Advertisement

Quick Links

USER'S MANUAL
UNINTERRUPTIBLE POWER SUPPLY (UPS)
Modules 10-200kVA
ADAPT

Advertisement

Table of Contents
loading

Summary of Contents for Salicru ADAPT Series

  • Page 1 USER'S MANUAL UNINTERRUPTIBLE POWER SUPPLY (UPS) Modules 10-200kVA ADAPT...
  • Page 2: Table Of Contents

    5.2.2. Unpacking Power Module 10.4. EPO PROCEDURE 6. POSITIONING 11. MAINTENANCE 6.1. POSITIONING CABINET 11.1. PRECAUTIONS 6.2. INSTALLING POWER MODULE 11.2. INSTRUCTION FOR MAINTAINING POWER MODULE 6.3. BATTERY 11.3. INSTRUCTION FOR MAINTAINING BYPASS MODULE 6.4. CABLE ENTRY 11.4. REPLACING DUST FILTER (OPTIONAL) SALICRU...
  • Page 3 12. PRODUCT SPECIFICATION 12.1. APPLICABLE STANDARDS 12.2. ENVIRONMENTAL CHARACTERISTICS 12.3. ENVIRONMENTAL PROPERTIES 12.4. ELECTRICAL CHARACTERISTICS (INPUT RECTIFIER) 12.5. ELECTRICAL CHARACTERISTICS (INTERMEDIATE DC LINK) 12.6. ELECTRICAL CHARACTERISTICS (INVERTER OUTPUT) 12.7. ELECTRICAL CHARACTERISTICS (BYPASS INPUT) 12.8. EFFICIENCY 12.9. DISPLAY AND INTERFACE MANUAL DE USUARIO ADAPT SISTEMA DE ALIMENTACIÓN ININTERRUMPIDA...
  • Page 4: Introduction

    We remain at you entire disposal for any further information or any query you should wish to make. Yours sincerely. SALICRU The equipment here described can cause important • physical damages due to wrong handling. This is why, the installation, maintenance and/or fixing of itself must be done by our staff or qualified personnel exclusively.
  • Page 5: Information For Safety

    2. INFORMATION FOR SAFETY. 2.1.1. Conventions and used symbols. Some symbols can be used and shown in the equipment and/or 2.1. USING THIS MANUAL. in the description of this user's manual. The generic information of the equipment is supplied in digital For more information, see section 1.1.1 of EK266*08 document as regards to «Safety instructions».
  • Page 6: Quality And Standard Guarantee

    WARNING!: SLC ADAPT. This is a category C3 UPS product. This is a product for commercial and industrial application in the second environment - installation restrictions or additional measures may be needed to prevent distur- bances. SALICRU...
  • Page 7: Presentation

    4. PRESENTATION. 4.3.1. Normal Mode The inverter of power modules continuously supply the critical 4.1. SYSTEM CONFIGURATION AC load. The rectifier/charger derives power from the AC mains input source and supplies DC power to the inverter while si- The Modular UPS is configured by the following part: Power multaneously FLOAT or BOOST charging its associated backup modules, Bypass &...
  • Page 8 LCD turned off. 4.3.5. ECO Mode To improve system efficiency, UPS rack system works in Bypass mode at normal time, and inverter is standby. When the uti- lity fails, the UPS transfers to Battery Mode and the inverter powers the loads. SALICRU...
  • Page 9 Item Components Quantity/ pcs Remark Cabinet Manual Bypass Requisite, factory installed System display Requisite, factory installed Bypass & Monitoring Requisite, factory installed module Dust filter Optional. Power module Power module 1-10 Requisite, installed on site. Table 1. UPS Configuration. System Unit Power Connection Bypass...
  • Page 10 Surge Protection System Unit Power Connection Bypass Moudle Power Module Fig. 10. 3 module cabinet UPS Structure SALICRU...
  • Page 11: Installation Instruction

    5. INSTALLATION INSTRUCTION If external batteries are to be used, the battery circuit breakers (or fuses) must be mounted as close as possible to the batte- ries, and the connecting cables should be as short as possible. 5.1. LOCATION 5.1.2. Site Selection As each site has its requirements, the installation instructions in this section are to act as a guide for the general procedures Ensure the ground or installation platform can bear the weight...
  • Page 12 Fig. 11. Dimensions 120KVA. Fig. 12. Dimensions 60KVA. SALICRU...
  • Page 13 Fig. 13. Dimensions 200KVA. MANUAL DE USUARIO ADAPT SISTEMA DE ALIMENTACIÓN ININTERRUMPIDA...
  • Page 14: Moving And Unpacking Of The Cabinet

    Fig. 17. Fig. 15. Disassemble the case Remove the protective foam around the cabinet Fig. 17. Place on platform smoothly Cut the plastic packing belt and scotch tape to open the carton. (See Fig. 18). SALICRU...
  • Page 15 1- Carton 2- Foam packing Fig. 18. Open the carton Remove the foam cover (See Fig. 19). 1- Carton 2- Foam packing 3- Power module Fig. 19. Remove the foam cover. Take out the UPS with plastic package and dismantle the packaging materials.
  • Page 16: Positioning

    5- 1# Power module 6- Mounting holes weight over a larger area. For instance, cover the floor with iron plate or increase the supporting area of the anchor bolts. Fig. 21. Installing power module SALICRU...
  • Page 17: Battery

    Note: The installing method of bypass module is the same as the power module. 6.3. BATTERY The battery set can be based between 36 and 44 blocks con- nected in serial, but it will always be an even number due to the internal structure of the equipment, which needs a mid tap or central point (neutral) of them.
  • Page 18: Connecting Power Cables

    Check to make sure there is no mistake and re-install all the Specified temperature sensor is required for temperature detection (R25=5Ohm, protective covers. B25/50=3275), please confirm with the manufacturer, or contact local maintenance engineers when placing an order. Table 4. Description of Input Dry Contact SALICRU...
  • Page 19 Remote EPO Input Port • The UPS has an Emergency Power OFF (EPO) function. This function can be activated by pressing a button on the control panel of the UPS or through a remote contact provided by the user. The EPO pushbutton is protected by a hinged plastic cover. J4 is the input port for remote EPO.
  • Page 20 Table 9. will be open during warning J10-2 UTILITY_FAIL_NO Mains failure warning relay (normally open) will be closed during warning J10-3 UTILITY_FAIL_GND Common terminal Table 10. Utility failure warning dry contact interface description. Fig. 33. Integrated warning dry contact SALICRU...
  • Page 21: Overview

    7. INSTALLATION OF UPS RACK SYSTEM AND 7.2.3. Parallel Signal Board PARALLEL SYSTEM Installation of parallel signal board 7.1. OVERVIEW The parallel signal board BJ is installed at the rear of the static switch power module. Refer to fig.36 and 37. The single or parallel system should be installed according to the installation procedures of the UPS rack module system and the requirements in this Chapter.
  • Page 22: Control Cables

    Refer to fig. 38. Parallel Signal Board BJ Parallel Signal Board BJ Rack Modular system UPS1 Rack Modular system UPS2 Fig. 38. Connection of Parallel Control Cables of “1+N” System SALICRU...
  • Page 23: Installation Drawing

    8. INSTALLATION DRAWING To User Safety SNMP Card SNMP Ground RS232 RS485 Connect to Critical Load Batt. Temperature ENV. Temperature Main Supply Power Cables Rack Modular UPS system Bypass Supply Batt. Low Alarm General Alarm To External Battery Connection Utility Fail Fig.
  • Page 24 Fig. 41. Power Connection of Module System UPS: 200KVA UPS power connection Fig. 45. Static Bypass Module Fig. 42. Power Connection of Module System UPS: 120KVA UPS power connection Fig. 43. Power Connection of Module System UPS: 60KVA UPS power connection SALICRU...
  • Page 25: Operator Control And Display Panel

    9. OPERATOR CONTROL AND DISPLAY PANEL This chapter introduces the functions and operation instructions of the UPS operator control and display panel in detail, and provides LCD display information, including LCD display types, detailed menu information, prompt window information and UPS alarm list. Fig.
  • Page 26: Functional Keys

    The LED on the front panel of battery pack indicates battery pack Fig. 47. Main LCD Display status. If battery fuse in battery pack is broken, LED changes to be red. Customer must contact with our local distributer to maintain it. SALICRU...
  • Page 27 The description of LCD icon is shown in table.17: Icon Description Bypass parameter(voltage, current, PF, frequency) Main input parameter(voltage, current, PF, frequency) History log, system information Function setting (display calibration, password setting, time setting, date format, communication protocol and language setting), system setting (used only for manufacturer) Battery data, battery parameter setting (used for service engineer) Test (battery self-test, battery maintenance) Functional keys used by service staff (fault clear, history log clear, mute on or off, manual transfer...
  • Page 28 The LCD menu tree is shown as below. Please refer to table. 17: Item Description of UPS Menu Fig. 48. Menu Tree Structure SALICRU...
  • Page 29: Changing The Current Date And Time

    9.5. LANGUAGE SELECTION 9.6. CHANGING THE CURRENT DATE AND TIME The LCD menus and data display are available in 4 languages: To change system date and time: Simple Chinese, English, Korean, Traditional Chinese. In main menu, press to enter in function setting Perform the following procedure to select a language needed: menu in the LCD screen.
  • Page 30 Rectifier software version Inverted software version Inverter software version UPS system information Serial No. The serial NO set when delivery from the factory Rated information System rated information Module model Module model Table 19. Item Description of UPS Menu SALICRU...
  • Page 31: Ups Event Log

    9.9. UPS EVENT LOG The follow table. 20 gives the complete list of all the UPS events displayed by history record window and current record window. UPS events Description FaultClr Manually clear fault Log Clr Manually clear History log Load On UPS Inverter feeds load Load On Byp Bypass feeds load...
  • Page 32 2. If this alarm is true, measure the actual output current to confirm if the displayed value is correct. Disconnect non-critical load. In parallel system, this alarm will be triggered if the load is severely imbalanced. SALICRU...
  • Page 33 UPS events Description N# Power Module Inverter Over Load Timeout. The UPS overload status continues and the overload times out. Note: The highest loaded phase will indicate overload timing-out first. When the timer is active, then the alarm “unit over load” should also be active as the load is above nominal.
  • Page 34: Introduction

    10.2.1. Start-Up Procedure Table 23. Battery charged This procedure must be followed when turning on the UPS from 10.2.2. Battery Start a fully powered down condition. Verify that the battery is properly connected. The operating procedures are as follows: SALICRU...
  • Page 35: Procedure For Switching The Ups Between

    Press the cold start-up button (see as fig. 50) under the Note: rectifier input circuit breaker for 1 seconds Pressing the Alarm Silence button cancels the audible At this point, the LCD displays the start screen, press cold alarm but leaves the warning message displayed until the start-up button again.
  • Page 36: Maintenance

    Close maintenance bypass switch, the UPS power will be supplied by maintenance bypass. 1- Dust filter Pull out the bypass module and the load is powered through 2- Bracket maintenance bypass. Fig. 51. Dust filter on the back side of front door SALICRU...
  • Page 37 12. PRODUCT SPECIFICATION This chapter provides UPS product specification. 12.1. APPLICABLE STANDARDS The UPS has been designed to conform to the following European and international standards: Item Normative reference General safety requirements for UPS used in operator access areas EN-IEC62040-1-1/AS 62040-1-1 Electromagnetic compatibility (EMC) requirements for UPS EN-EC62040-2/AS 62040-2(C3) Method of specifying the performance and test requirements of UPS...
  • Page 38 Factory setting is 50Hz. Commissioning engineers can set to 60Hz. EN50091-3(1.4.58) crest ratio is 3: 1. IEC62040-3/EN50091-3 including 0%~100%~0% load transient, the recovery time is half circle to within 5% of stable output voltage. Table 29. Inverter Output (to Critical Load) SALICRU...
  • Page 39 12.7. ELECTRICAL CHARACTERISTICS (BYPASS INPUT) Rated capacity(kVA) 380/400/415 Rated AC Voltage (Vac) three-phase four-wire, sharing neutral with the rectifier input and providing neutral reference for the output 380V Rated 400V current 415V 125% load, long term 130% load, 1 hour Overload 150% load, 6min 1000% load, 100ms...
  • Page 40 Avda. de la Serra 100 08460 Palautordera BARCELONA Tel. +34 93 848 24 00 Fax +34 93 848 22 05 services@salicru.com SALICRU.COM The Technical Service & Support (T.S.S.) network, Commercial network and warranty information are available in website: www.salicru.com Product Range...