Siemens SITRANS F Series Function Manual page 57

Profibus (from firmware 4.0) coriolis flowmeters
Hide thumbs Also See for SITRANS F Series:
Table of Contents

Advertisement

Table 2-18
Slot 13: Totalizer block 3
In‐
Parameter Name
dex
16
BLOCK_OBJECT
17
CURRENT_MODE Un‐
22
TOTAL
FCT030 Profibus (From firmware 4.0)
Function Manual, 06/2018, A5E39931906-AB
Data
Access
Annotation
Type
DS-32
Read only Constant block information used to identify the block type
Read only Set to "Out of service" if the TARGET_MODE parameter of the Physical
signed8
Block is set to "Out of service".
Available modes:
8: Automatic
128: Out of Service
101
Read only 32-bit floating point process value with quality code. The value follows
TOTAL_UNITS.
TOTAL and TOTAL_DOUBLE are always "on pair" i.e. both showing the
same totalized value but with a different precision.
Communication
2.10 Acyclic communication
57