Siemens SITRANS F Series Function Manual page 30

Profibus (from firmware 4.0) coriolis flowmeters
Hide thumbs Also See for SITRANS F Series:
Table of Contents

Advertisement

Communication
2.10 Acyclic communication
Index
Parameter name
47
UP‐
DATE_EVENT_MO
DE
48
NE107_COMMON
49
LINK_NE107_COM‐
MON
50
View_1
51
View_2
52
View_3
30
Data type
Access
[size]
Unsigned8
Read /
write
OctetString(6)
Read only
DS-69
Read /
write
Read only
Read /
write
Read /
write
Annotation
Holds the configuration for the behavior of the update event
flag in all status bytes
0: auto-acknowledge after 20 seconds.
1: manual acknowledge by means of parameter UP‐
DATE_EVENT_ACK
Detailed information of the device, bitwise coded. Allows set‐
ting of diagnostic flags specified by the NAMUR recommen‐
dation NE107 comprising common device diagnostics. The
device type specific diagnostics are allocated to the respec‐
tive transducer block (module/submodule) that characterizes
the device type mainly.
Indicates / controls the reaction of the device on device spe‐
cific diagnostic events.
Parameter to read the following block parameters at once:
· BLOCK_OBJECT
· OrderID
· SOFTWARE_REVISION
· HARDWARE_REVISION
· VendorID
· DeviceID
· IM_Serial_Number
· IM_Profile_ID
· IM_Profile_Specific_Type
Parameter to read the following block parameters at once:
· CURRENT_MODE
· DIAGNOSIS
· IM_Revision_Counter
· STARTUP_PARAM_VALIDITY
· BUS_ADDRESS
· IDENT_NUMBER
· BAUD_RATE
· WRITE_PROTECTION
· NE107_COMMON
Parameter to read and write the following block parameters
at once:
· IM_Tag_Function
· IM_Tag_Location
· IM_Descriptor
· LANGUAGE
· IM_Date
· IDENT_NUMBER_SELECTOR
Function Manual, 06/2018, A5E39931906-AB
FCT030 Profibus (From firmware 4.0)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans fct030

Table of Contents