Machine Electrical Connection
AUTO
OFF
(Left to Right Cabinet Shown)
Steam Heat Blower dryer control cabinet.
The steam inlet connection is 3/4" NPT rated at 85 lbs./hr. at 15-30 PSI.
Steam Heat Blower Dryer Steam Condensate Connection
The steam connection is 1/2" NPT return to drain or boilder (no back pressure).
Steam Heat Blower Dryer Electrical Connections
To connect main power:
1.
Remove the control cabinet cover and locate
the main terminal block (MTB) in the corner of
the cabinet.
Refer to the Machine Electrical Connection
2.
Data Plate located near the main terminal block
and make sure that the incoming power supply
matches the machine's electrical requirements.
3.
Connect the incoming 3-phase power as shown
in the illustration above.
4.
Reconnect the cables between the dishwasher
and the blower dryer after mounting the blower
dryer to the dishwasher. These cables were
disconnected prior to shipment and rolled back
behind the dishwasher control cabinet.
Steam Heat Blower Dryer Steam Connection
Installation
THREE PHASE
POWER CONNECTION
208/240/480/575V/60/3
L1
L2
L3
LINE IN
Steam Heat Main terminal block (MTB).
GRD