Message
System OK
Standby
+5V PS OV
-5V PS OV
-2V PS OV
+24V PS OV
-24V PS OV
+12V PS OV
-12V PS OV
+5V PS UV
-5V PS UV
-2V PS UV
+24V PS UV
-24V PS UV
+12V PS UV
-12V PS UV
FAN SPEED
AMB TEMP H
SLOT XX T
IACKX CNT
BERR CNT
SYSFAIL
ACFAIL
PON TIME
TOT PON TM
FILTER
Using The Enhanced Monitoring System 4-28
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table 4-8 Front Panel Status Messages

AC Power switch is ON, nothing out-of-tolerance
AC power switch is OFF, nothing out-of-tol
+5V power supply over-voltage condition
-5.2V power supply over-voltage condition
-2V power supply over-voltage condition
+24V power supply over-voltage condition
-24V power supply over-voltage condition
+12V power supply over-voltage condition
-12V power supply over-voltage condition
+5V power supply under-voltage condition
-5.2V power supply under-voltage condition
-2V power supply under-voltage condition
+24V power supply under-voltage condition
-24V power supply under-voltage condition
+12V power supply under-voltage condition
-12V power supply under-voltage condition
Fan speed is out of tolerance
Ambient Temperature is too high
Slot XX temperature rise is too high
(XX will be "C0 to C5", or "B0 to B2")
Interrupt Acknowledge Line X count reached
(X will be "1" to "7")
Bus Error count reached
SYSFAIL* line asserted
ACFAIL* line asserted
Elapsed power-on time limit reached
Elapsed cumulative power-on time limit reached
Filter service time limit reached
Meaning