Figure 3-4, Using Remote Power On/Standby Switching

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Pin
15
7,11
1.
Connect a user supplied cable (or
equivalent) between J415 (female 15
DSUB) and a remote switch, or open
collector driver. The switch (or driver)
should connect to J415 pin 15 (INHIBIT*)
and to one of the GND pins.
2.
Complete Steps in Figure 3-3 Powering
On The Mainframe.
3.
Place
in
Standby,
mainframe off, by closing remote switch
shorting pin J415-15 to Logic Ground
(INHIBIT* to GND) or by driving J415-15
to a TTL low with an open collector driver
which can sink 5mA of current. The OC
voltage at J415-15 is # 30 VDC.
4.
Opening
the
deasserting the open collector driver) re-
applies DC power to the mainframe
(Power On) provided the front power
switch is in the on position.
Function
Remote INHIBIT*
Logic Ground (GND)
DC
power
to
remote
switch
(or
Operating The 1269 3-5