Racal Instruments 1264C User Manual

6-slot vxibus mainframe
Table of Contents

Advertisement

Quick Links

6-SLOT VXIbus MAINFRAME
Tel: (800) 722-2528, (949) 859-8999; Fax: (949) 859-7139
5730 Northwest Parkway Suite 700, San Antonio, TX 78249
Tel: +33 (0)1 39 23 22 22; Fax: +33 (0)1 39 23 22 25
29-31 Cobham Road, Wimborne, Dorset BH21 7PF, United Kingdom
Tel: +44 (0) 1202 872800; Fax: +44 (0) 1202 870810
Racal Instruments Group Limited, Technologie Park, D-51429 Bergisch Gladbach
PUBLICATION DATE: February 24, 2003
Copyright 1998 by Racal Instruments, Inc. Printed in the United States of America. All rights reserved.
This book or parts thereof may not be reproduced in any form without written permission of the publisher.
USER MANUAL
MODEL 1264C
PUBLICATION NO. 980827
RACAL INSTRUMENTS
United States
(Corporate Headquarters and Service Center)
4 Goodyear Street, Irvine, CA 92618
Tel: (210) 699-6799; Fax: (210) 699-8857
Europe
(European Headquarters and Service Center)
18 Avenue Dutartre, 78150 LeChesnay, France
Via Milazzo 25, 20092 Cinisello B, Milan, Italy
Tel: +39 (0)2 6123 901; Fax: +39 (0)2 6129 3606
Tel: +49 2204 844205; Fax: +49 2204 844219
info@racalinstruments.com
sales@racalinstruments.com
helpdesk@racalinstruments.com
http://www.racalinstruments.com
info@racalinstruments.de
www.racalinstruments.de

Advertisement

Table of Contents
loading

Summary of Contents for Racal Instruments 1264C

  • Page 1 PUBLICATION DATE: February 24, 2003 Copyright 1998 by Racal Instruments, Inc. Printed in the United States of America. All rights reserved. This book or parts thereof may not be reproduced in any form without written permission of the publisher.
  • Page 2 THANK YOU FOR PURCHASING THIS RACAL INSTRUMENTS PRODUCT. For this product, or any other Racal Instruments product that incorporates software drivers, you may access our web site to verify and/or download the latest driver versions. The web address for driver downloads is: http://www.racalinstruments.com/downloads...
  • Page 3 Authorization is required from Racal Instruments before you send us your product for service or calibration. Call your nearest Racal Instruments support facility. A list is located on the last page of this manual. If you are unsure where to call, contact Racal Instruments, Inc. Customer Support Department in Irvine, California, USA at 1-800-722-3262 or 1-949-859-8999 or via fax at 1-949-859-7139.
  • Page 4 FOR YOUR SAFETY Before undertaking any troubleshooting, maintenance or exploratory procedure, read carefully the WARNINGS and CAUTION notices. This equipment contains voltage hazardous to human life and safety, and is capable of inflicting personal injury. If this instrument is to be powered from the AC line (mains) through an autotransformer, ensure the common connector is connected to the neutral (earth pole) of the power supply.
  • Page 6 This page was left intentionally blank.
  • Page 7: Table Of Contents

    500 Watts Usable DC Power....................1-5 Positive Pressure Cooling System................... 1-6 System Monitor ........................1-7 Rack Mount Options........................ 1-8 Backplane ..........................1-8 Items Shipped With The 1264C....................1-9 Spares & Optional Equipment ....................1-9 Chapter 2 .......................... 2-1 CONFIGURING THE 1264C....................... 2-1 Using This Chapter........................
  • Page 8 Monitoring Basics........................3-3 Backplane Connections.....................3-4 Basic Functional Check......................3-7 Chapter 4 ...........................4-1 UNDERSTANDING THE 1264C ....................4-1 Overview ..........................4-1 Power Supply ...........................4-1 Power Supply Interconnections.....................4-1 Power Supply Protections.....................4-3 Backplane ..........................4-3 AC Interface ..........................4-4 Cooling System ........................4-4 (Freestanding Unit Description) ....................4-4 Cooling The Power Supply ....................4-4 System Monitor ........................4-4...
  • Page 9 Trouble-shooting The 1264C....................5-12 Assembly Drawings ....................... 5-14 Parts List ..........................5-44 Chapter 6 .......................... 6-1 PRODUCT SUPPORT ........................ 6-1 Product Support ........................6-1 Warranty ..........................6-1 Support Offices ........................6-2 Appendix A ..........................A-1...
  • Page 10 Figure 5-4, Loosening The 14 Screws..................5-7 Figure 5-5 Removing and Replacing The AC Mains Fuse ............5-9 Figure 5-6, Card Guide Removal and Replacement ..............5-11 Figure A-1 Mainframe Worst Case Slot Cooling Curve ............... A-3 Figure A-2 View of 1264C with Rack Mount Option ..............A-6...
  • Page 11 List Of Tables Table 1-1 1264C Available DC Current ..................1-5 Table 3-1 Monitoring Basics......................3-3 Table 3-2 P1 Connector Pinouts ....................3-4 Table 3-3 P2 Connector Pinouts For All Non-Slot 0 Locations ............ 3-5 Table 3-4 P2 Connector Pinouts for VXIbus Slot 0 ..............3-6 Table 3-5 Power Supply Voltages at the P1 and P2 Connectors..........
  • Page 12 This page was left intentionally blank.
  • Page 13: Chapter 1

    Chapter 1 GETTING STARTED The Model 1264C 6-Slot Mainframe is a 6-slotVXIbus Mainframe. Product The 1264C can accommodate 6 C-size VXI modules. The Model Description 1264C fully complies with the VXIbus Specification Revision 2.0 (and earlier) requirements and is VXIplug&play compatible...
  • Page 14: Portable Bench Top Mainframe

    1264C User Manual The 1264C is a portable high performance 6-slot VXI mainframe Portable Bench (21.31L x 8.71W x 16.75H inches). Top Mainframe Figure 1-1, 1264C Portable Mainframe In Bench Top Configuration. Getting Started1-2 Racal Instruments © 1998...
  • Page 15: Rack Mount Configuration (5U Footprint)

    1264C User Manual The 1264C mainframe is designed for rack mounting in a 5U tall Rack Mount rack space. Configuration (5U Footprint) Figure 1-2, 1264C Rack Mount (5U Tall) Configuration Racal Instruments © 1998 Getting Started 1-3...
  • Page 16: Modular Mainframe Design

    1264C User Manual The 1264C highly modular design includes a wireless power Modular interface between the power supply and the VXI backplane. The Mainframe result is a low MTTR and high MTBF. Design Figure 1-3, Modular Service Friendly Mainframe Design Features.
  • Page 17: Watts Usable Dc Power

    1264C User Manual Figure 1-4 depicts the 1264C mainframe’s 500Watt modular power 500 Watts supply. Table 1-1 lists the available DC current for each VXI Usable DC voltage. Power Figure 1-4, 1264C 500 Watt Modular Power Supply. VXI Voltage Available DC Current 45 Amps -5.2V...
  • Page 18: Positive Pressure Cooling System

    1264C User Manual The 1264C uses forced air positive pressure cooling to direct air Positive to the VXI modules. Pressure Figure 1-5 details the cooling system. Cooling System Figure 1-5, 1264C Positive Pressure Cooling System. Getting Started1-6 Racal Instruments © 1998...
  • Page 19: System Monitor

    The System Monitor features include a window comparator on System Monitor each VXIbus voltage, fan failure indicator, and a power supply intake air temperature monitor. Each monitor includes a front panel LED annunciator. System Monitor Figure 1-6, 1264C System Monitor Racal Instruments © 1998 Getting Started 1-7...
  • Page 20: Rack Mount Options

    Option 01 includes rack mount ears, and slides. Options 04 consist of rack mount ears only. Backplane The 1264C backplane can accommodate up to six C-size VXI modules. The 1264C has a jumperless auto-configurable backplane using active-automatic daisy chaining for the VME Interrupt acknowledge and bus grant daisy chain signal lines.
  • Page 21: Items Shipped With The 1264C

    1264C User Manual Items Shipped With The 1264C Item Part Number Instruction Manual 980827 Power Cable 600620 Standard 600858 w/Option 71 Spares & Optional Equipment Spares Ordering Information Model Description Part Number Card Guide Cover Spare Card Guide Cover (block air through...
  • Page 22 1264C User Manual This page was left intentionally blank. Getting Started1-10 Racal Instruments © 1998...
  • Page 23: Chapter 2

    Installation configuration information optional equipment is provided with the option. When the standard 1264C is shipped, it is configured for 120 VAC AC Mains operation. Voltage selection switch S400 is set to the 115VAC Power position. Should it be necessary to replace the AC mains fuse (F400), refer to Chapter 5: Removal and Replacement of the AC Mains Fuse.
  • Page 24: Installing Vxi Modules

    (1). Apply a slight downward pressure on top of the cover (with the other hand) at the rear to engage the hook into the cardguide. Configuring The 1264C 2-2 Racal Instruments © 1998...
  • Page 25: Installation Of Rack Mount Options

    Refer to page 5-41 for installation of Option 01, Rack Ears and Installation of Slides (P/N 407670). Rack Mount Refer to page 5-42 for installation of Option 04, Rack Ears only Options (P/N 407671). Racal Instruments © 1998 Configuring The 1264C 2-3...
  • Page 26: Installing Blanking Panels

    (P/N 404836) into unused or C-size empty slots. Secure Blanking with two captive mounting screws. Refer to Figure 2-3. Panels Mounting Screws (Top and Bottom) Blank Panel Figure 2-2, Blanking Panels Configuring The 1264C 2-4 Racal Instruments © 1998...
  • Page 27: Connecting Chassis Ground

    2. Attach the opposite end of the wire to permanent earth ground earth (or to the ground of one or more instruments in the system) using toothed washers or a toothed lug. Chassis (Safety) Grounding Screw Figure 2-3, Connecting Safety Ground Racal Instruments © 1998 Configuring The 1264C 2-5...
  • Page 28 1264C User Manual This page was left intentionally blank. Configuring The 1264C 2-6 Racal Instruments © 1998...
  • Page 29: Chapter 3

    Perform basic functional check of the mainframe VXI voltages. · Reference pin connections for VXI P1 and P2 Connectors. 1264C Front Panel Monitor LED indicators S100 AC MAINS Switch Figure 3-1, 1264C Front View Racal Instruments © 1998 Operating The 1264C 3-1...
  • Page 30: 1264C Rear View

    2. Connect the AC Power cord at J400 to the AC power source – ON/OFF 115 VAC (if S400 is set for 115VAC) for the standard 1264C, or 230 VAC (if S400 is set for 230VAC) if Option 71 is installed.
  • Page 31: Monitoring Basics

    1264C User Manual WARNING Option 71 (P/N 407676) is required for applications powered by 230 VAC power. The 1264C is configured for 230 VAC operation ONLY when Option 71 is ordered Refer to Figures 3-1 and 3-2 while using Table 3-1 to interpret Monitoring system monitor information.
  • Page 32: Backplane Connections

    1264C User Manual Table 3-2 shows the P1 connector pinouts for all slots in the Backplane 1264C. Table 3-3 shows the P2 connector pinouts for all non-slot Connections 0 slots. Table 3-4 shows the P2 connector pinouts for the VXIbus slot 0.
  • Page 33: Table 3-3 P2 Connector Pinouts For All Non-Slot 0 Locations

    LBUSC04 LBUSA05 LBUSC05 -5.2V LBUSA06 LBUSC06 LBUSA07 LBUSC07 LBUSA08 LBUSC08 LBUSA09 LBUSC09 -5.2V -5.2V LBUSA10 LBUSC10 LBUSA11 LBUSC11 TTLTRG0* TTLTRG1* TTLTRG2* TTLTRG3* TTLTRG4* TTLTRG5* TTLTRG6* TTLTRG7* RSV2 RSV3 MODID +24V SUMBUS -24V Racal Instruments © 1998 Operating The 1264C 3-5...
  • Page 34 LBUSC04 MODID07 LBUSC05 -5.2V MODID06 LBUSC06 MODID05 LBUSC07 MODID04 LBUSC08 MODID03 LBUSC09 -5.2V -5,2V MODID02 LBUSC10 MODID01 LBUSC11 TTLTRGO* TTLTRG1* TTLTRG2* TTLTRG3* TTLTRG4* TTLTRG5* TTLTRG6* TTLTRG7* RSV2 RSV3 MODID00 +24V SUMBUS -24V Operating The 1264C 3-6 Racal Instruments © 1998...
  • Page 35: Basic Functional Check

    Note that the “Voltage Range” values in Table 3-5 are identical to the VXIbus Specification. The voltage range limits provided in Table 3-1 refer to the voltage monitor indicators on the 1264C front panel. The monitor will detect a voltage error when the limit is ±...
  • Page 36 1264C User Manual This page was left intentionally blank. Operating The 1264C 3-8 Racal Instruments © 1998...
  • Page 37: Chapter 4

    · Backplane · Cooling System · System Monitor Figure 4-1 shows the functional block diagram of the 1264C Mainframe. The power supply accepts power from the AC mains and converts Power Supply it to DC to power the following: ·...
  • Page 38: Figure 4-1, Functional Block Diagram For 1264C Mainframe

    E1 TO E14 P300 P301 J300 J301 PS1 P/S PS1-RS PS1-PF MONITOR (405141) S100 AC Mains Switch TEMP LED FAN LED VOLTAGE MONITOR LED's Figure 4-1, Functional Block Diagram For 1264C Mainframe Understanding The 1264C 4-2 Racal Instruments © 1998...
  • Page 39: Power Supply Protections

    Connects the VXI extension signals across P2 rows A and C to all slots. · Connects to the system monitor board through a 14-pin ribbon cable between J50 on the backplane and J301 on the power supply assembly (407645). Racal Instruments © 1998 Understanding The 1264C 4-3...
  • Page 40: Ac Interface

    1264C User Manual AC Power supplied to the 1264C at J400 is fused at F400 and AC Interface routed to switch S100 (main On/Off). The secondary side of S100 is routed to the power supply PS1 and to the cooling fan F1. The...
  • Page 41: Figure 4-2, System Monitor Block Diagram

    X10 Gain/ Airflow/Ambient Inverter/LED Comparator Thermistor Bridge Circuit Driver's Circuit Comparator Inverter/LED Temperature Sensor Circuit Driver's ACFAIL*/SYSRESET* Power-on Power Fail ACFAIL*/SYSRESET* and Power Down Timing Circuit Figure 4-2, System Monitor Block Diagram Racal Instruments © 1998 Understanding The 1264C 4-5...
  • Page 42: Voltage Monitor

    SYSRESET are generated with the appropriate timing relationship – see the VME specification revision C-1, or later. The signals are Signals then routed to the backplane through the 14-pin ribbon cable between J1 (monitor) and J50 on the backplane. Understanding The 1264C 4-6 Racal Instruments © 1998...
  • Page 43: Chapter 5

    1264C, removing and Chapter replacing mainframe components, and isolating problems to the module level. Refer to Chapter 4 Understanding The 1264C for theory of operation information. The 1264C does not require calibration. To verify proper operation Calibration see the Basic Functional Check section in Chapter 3.
  • Page 44: Inspection And Cleaning

    1264C User Manual CAUTION Many components within mainframe susceptible to static discharge damage. Service the mainframe only in a static-free environment. Observe standard handling precautions for static-sensitive devices while servicing the mainframe. Always wear a grounded wrist strap, or equivalent, while servicing the mainframe.
  • Page 45: Cleaning The Fan Filters

    1264C User Manual CAUTION Avoid getting moisture inside the mainframe during exterior cleaning - use just enough moisture to dampen the cloth. Do not wash the front or rear panel connectors or switches. Cover these components while cleaning the mainframe.
  • Page 46: Modular Component Removal And Replacement

    Always power off the mainframe and disconnect the power cord before cleaning servicing mainframe. The only tools required to disassemble the 1264C chassis to the Tools Required module level are a medium flat blade and Phillips screwdriver. Maintenance 5-4 Racal Instruments © 1998...
  • Page 47: Removal And Replacement Of The Fan Assembly

    1264C User Manual The fan assembly may be removed and replaced as described in Removal and the following steps. Refer to Figure 5-2. Replacement of The Fan Assembly Remove Screws 4 places Remove Screws 6 Places Power Cord S400 Connection...
  • Page 48: Removal And Replacement Of The Power Supply Assembly

    1264C User Manual To remove and install the power supply assembly from the Removal and mainframe. Refer to Figure 5-3 and perform the steps below. Replacement of The Power Supply Assembly Power Supply Retaining Screws (4) Figure 5-3, Removing The Power Supply Maintenance 5-6 Racal Instruments ©...
  • Page 49: Figure 5-4, Loosening The 14 Screws

    1264C User Manual 1. Unplug the AC power cord from the rear panel of the 1264C and remove the rear panel/fan assembly following the instructions from Removal and Replacement of The Fan Assembly, above 2. Disconnect the in-line connector (J301/P301) by grasping each mating half and gently pulling apart.
  • Page 50 1264C User Manual 5. Push at J300 on the rear of the supply assembly to slide the supply assembly towards the front of the mainframe. 6. Firmly grasp the tab (handle) at the bottom front of the power supply assembly and pull forward using a slight side to side rocking motion.
  • Page 51: Removal And Replacement Of The Ac Mains Fuse

    1264C User Manual Complete the steps below while referring to Figure 5-5 Removal and Replacement of The AC Mains Fuse WARNING To avoid electrical shock, the AC mains power input must be disconnected before replacement of the fuse. AC Mains...
  • Page 52 1264C User Manual 1. Ensure AC mains input (J400) is disconnected. 2. Insert flat blade screwdriver into fuse carrier slot at F400 in power supply rear panel and rotate counter clockwise to remove. 3. To replace fuse, insert the fuse carrier and fuse assembly into the fuse housing opening for F400 on power supply.
  • Page 53: Removing And Replacing The Card Guides

    1264C User Manual Complete the steps below while referring to Figure 5-6 to remove Removing and and replace the card guides. The procedure applies to top and Replacing The bottom card guides. Card Guides Figure 5-6, Card Guide Removal and Replacement 1.
  • Page 54: Trouble-Shooting The 1264C

    To troubleshoot the 1264C VXIbus mainframe to its component Trouble- module level use Table 5-1 and Understanding the 1264C in shooting The Chapter 4. 1264C “Fault condition” referenced in the PROBLEM column of Table 5-1 occurs when the monitored system status function (Voltage, Temperature, or Fan) is outside of its specified tolerance.
  • Page 55: Table 5-1 Troubleshooting

    WHAT TO DO Unit does not Power On · · 1264C mainframe not Make sure that the 1264C is connected connected to power to a live electrical outlet and the AC source. power switch is on. Try operating another piece of equipment from this outlet.
  • Page 56: Assembly Drawings

    1264C, Top Assembly................5-15 407646 1264C, Enclosure..................5-17 407645 1264C, Power Supply................5-20 405130 PCB Assy, 6-Slot Backplane ..............5-21 435130 Schematics, 1264C 6-Slot Backplane .............5-22 405141 PCB Assy, Monitor ..................5-36 435141 Schematics, 1264C Monitor ..............5-37 407670 Option 01, Rack Ears and Slide ..............5-41 407671 Option 04, Rack Ears Only..............5-42...
  • Page 57 1264C User Manual Racal Instruments © 1998 Maintenance 5-15...
  • Page 58 1264C User Manual Maintenance 5-16 Racal Instruments © 1998...
  • Page 59 1264C User Manual Racal Instruments © 1998 Maintenance 5-17...
  • Page 60 1264C User Manual Maintenance 5-18 Racal Instruments © 1998...
  • Page 61 1264C User Manual Racal Instruments © 1998 Maintenance 5-19...
  • Page 62 1264C User Manual Maintenance 5-20 Racal Instruments © 1998...
  • Page 63 1264C User Manual Racal Instruments © 1998 Maintenance 5-21...
  • Page 64 1264C User Manual Maintenance 5-22 Racal Instruments © 1998...
  • Page 65 1264C User Manual Racal Instruments © 1998 Maintenance 5-23...
  • Page 66 1264C User Manual Maintenance 5-24 Racal Instruments © 1998...
  • Page 67 1264C User Manual Racal Instruments © 1998 Maintenance 5-25...
  • Page 68 1264C User Manual Maintenance 5-26 Racal Instruments © 1998...
  • Page 69 1264C User Manual Racal Instruments © 1998 Maintenance 5-27...
  • Page 70 1264C User Manual Maintenance 5-28 Racal Instruments © 1998...
  • Page 71 1264C User Manual Racal Instruments © 1998 Maintenance 5-29...
  • Page 72 1264C User Manual Maintenance 5-30 Racal Instruments © 1998...
  • Page 73 1264C User Manual Racal Instruments © 1998 Maintenance 5-31...
  • Page 74 1264C User Manual Maintenance 5-32 Racal Instruments © 1998...
  • Page 75 1264C User Manual Racal Instruments © 1998 Maintenance 5-33...
  • Page 76 1264C User Manual Maintenance 5-34 Racal Instruments © 1998...
  • Page 77 1264C User Manual Racal Instruments © 1998 Maintenance 5-35...
  • Page 78 1264C User Manual Maintenance 5-36 Racal Instruments © 1998...
  • Page 79 1264C User Manual Racal Instruments © 1998 Maintenance 5-37...
  • Page 80 1264C User Manual Maintenance 5-38 Racal Instruments © 1998...
  • Page 81 1264C User Manual Racal Instruments © 1998 Maintenance 5-39...
  • Page 82 1264C User Manual Maintenance 5-40 Racal Instruments © 1998...
  • Page 83 1264C User Manual Racal Instruments © 1998 Maintenance 5-41...
  • Page 84 1264C User Manual Maintenance 5-42 Racal Instruments © 1998...
  • Page 85 1264C User Manual Racal Instruments © 1998 Maintenance 5-43...
  • Page 86: Parts List

    1264C User Manual Parts List 407647 1264C, Top Assembly................5-45 407646 1264C, Enclosure..................5-46 407645 1264C, Power Supply ................5-47 405130 PCB Assembly, 6-Slot Backplane ............5-48 405141 PCB Assembly, Monitor ................5-49 407699 Conn Assembly, 50 Pin Low Profile ............5-50 Maintenance 5-44 Racal Instruments © 1998...
  • Page 87 1264C User Manual Assembly 407647 Low Level Code 03 Description 1264C, 6-SLOT 500W MAINFRAME –N Revision Date 2001-10-18 Revision J Component Description Qty Reqd 407645 POWER SUPPLY ASSY, 500W 1.000 407646 ENCLOSURE ASSY, 6-SLOT CHAS 1.000 600620 CABLE, POWER AC LINE 1.000...
  • Page 88 1264C User Manual Assembly 407646 Low Level Code 04 Description ENCLOSURE ASSY, 6-SLOT CHAS -D Revision Date 1999-06-29 Revision B Component Description Qty Reqd 405130 PCB ASSY, 6-SLOT BACKPLANE 1.000 456693 FILLER PANEL, LEFT, 6-SLOT 1.000 456694 KEY, LOCKOUT, 6 SLOT 2.000...
  • Page 89 1264C User Manual Assembly 407645 Low Level Code 04 Description POWER SUPPLY ASSY, 500W Revision Date 1998-10-28 Revision B Component Description Qty Reqd 405141 PCB ASSY,MONITOR 1.000 456680 PANEL,FRONT,PWR SUPPLY 1.000 456681 ENCLOSURE,PWR SUPPLY MTG 1.000 500271-545 WRTEF-STR14G-5-4-5-GRN/YEL 521000 WRTEF-STR16G-0-0-0 BLK...
  • Page 90 1264C User Manual Assembly 405130 Low Level Code 05 Description PCB ASSY, 6-SLOT BACKPLANE -N Revision Date 1999-08-26 Revision E Component Description Qty Reqd P304000005 DIODE 1N4002 6.000 000102 RSCC2-001.00K.25W005 2.000 000331 RSCC1-330.00H.25W005 2.000 000471 RSCC1-470.00H.25W005 2.000 000510 RSCC1-051.00H.25W005 10.000 010308 RSMF1-049.90H.25W001...
  • Page 91 1264C User Manual Assembly 405141 Low Level Code 05 Description PCB ASSY, MONITOR Revision Date 2000-04-06 Revision D Component Description Qty Reqd R-20-5771 RSCH1-010.00H.12W005 2.000 R-21-1802 CPCH2-0100.0N0050V20 29.000 010308 RSMF1-049.90H.25W001 3.000 040197 PTST2-CM010.0K-PC-TA 1.000 040332 PTST1-CM100.0H-PC-SA 1.000 050000-104 RSCH2-100.00K.06W005 1.000 050000-105 RSCH3-001.00M.06W005...
  • Page 92 1264C User Manual Racal Instruments, Inc. Assembly 407669 Conn Assy, 50 Pin, Low Profile Date 10/02/98 Revision A Component Description Qty Reqd 456701 BACKSHELL,50 PIN,LOW PROFILE -D BA 1.000 456702 STRAIN RELIEF,LOW PROFILE -D BA 1.000 601855-050-001 CONN~50 PIN PLUG,MODIFIED -D BA 1.000...
  • Page 93: Chapter 6

    For worldwide support and the office closes to your facility, refer to the Support Offices section on the following page. Use the original packing material when returning the 1264C to Warranty Racal Instruments for calibration or servicing. The original shipping crate and associated packaging material will provide the necessary protection for safe reshipment.
  • Page 94: Support Offices

    Tel: +44 (0) 1202 872800; Fax: +44 (0) 1202 870810 Via Milazzo 25, 20092 Cinisello B, Milan, Italy Tel: +39 (0)2 6123 901; Fax: +39 (0)2 6129 3606 Racal Instruments Group Limited, Technologie Park D-51429 Bergisch Gladbach Tel: +49 2204 844205; Fax: +49 2204 844219 Product Support 6-2 Racal Instruments ©...
  • Page 95 REPAIR AND CALIBRATION REQUEST FORM To allow us to better understand your repair requests, we suggest you use the following outline when calling and include a copy with your instrument to be sent to the Racal Instruments Repair Facility. Model Serial No.
  • Page 96 1264C User Manual This page was left intentionally blank. Product Support 6-4 Racal Instruments © 1998...
  • Page 97: Table A-1 Ac Input Specifications

    1264C User Manual Appendix A SPECIFICATIONS This chapter contains the complete specifications for the 1264C Specifications Mainframe. Table A-1, AC Input Specifications Characteristic Description Input Voltage Range 115 VAC ± 10% 230 VAC ± 10% (Switch settable at S400) Input Frequency Range...
  • Page 98: Table A-2 Dc Output Power

    1264C User Manual Table A-2, DC Output Power Characteristic Description Maximum Power Available 500 W, 0 C to 50 To Modules Derate 2.5%/ C above 50 Useable Power 790W DC Current Capacity (I Voltage (Steady-State Current) +24V +12 V +5 V...
  • Page 99: Figure A-1 Mainframe Worst Case Slot Cooling Curve

    1264C User Manual Table A-3, Cooling Characteristic Description Per Slot Cooling Capacity Typically 52W per VXI-8 rev 2.0 (for 10 C rise). Figure A- 1 shows the worst slot cooling curve of the mainframe. Cooling System Forced air circulation (positive pressurization).
  • Page 100: Table A-4 Safety

    1264C User Manual Table A-4, Safety Characteristic Description Safety Characteristics EN61010-1:1993+A2:1995 IEC Characteristics Installation Category II Pollution Degree 2 Safety Class 1 Table A-5, Environmental Characteristic Description Temperature Meets the limits stated in MIL-T-28800E for Type III, Class 5 Operating...
  • Page 101: Table A-6 Backplane

    1264C User Manual Table A-6, Backplane Characteristic Description Bus Grant/Interrupt Solid state, auto-configuring (jumper less) Acknowledge VXIbus CLK10 Distribution Full differential Table A-7, Mechanical Characteristic Description Overall Dimensions Standard Mainframe (7U) Height 16.75 in (42.6 cm) Width 8.7 in (22.1 cm) Depth 21.3 in (54.1 cm)
  • Page 102: Figure A-2 View Of 1264C With Rack Mount Option

    1264C User Manual Figure A-2, View of 1264C With Rack Mount Option Table A-8, System Monitoring Specifications, ( Typical ) Characteristics Description VXI Power Supply Voltage monitor ±10% Default Tolerance limits: V nominal 4% accuracy VXI Power Supply Intake air Temperature Default Tolerance limits: T >...

Table of Contents