Barco B-16 Mobile LED Installation Manual page 51

Table of Contents

Advertisement

Door stops
Door hinges
Nails
Walls
surrounding frames
nails
attachment to main frame
inside wall paneling
wall control room
Roof
attachment to side frames
attachment to display grid
Floor
attachment
holes for water evacuation
Display system
Pump
leaks
oil level
lever
attachment to frame
Rotation system
lubricate
attachment bolts 2x
Mast
functioning
oil losses of main cylinder
cylinder flexible
attachment to grid
Generator
general
motor
alternator
oil
gas - diesel
exhausts
fixing
state
C = Control
L = Lubricate
T = Tighten
Cl = Clean
After 50h00 the diesel generator needs to get its first maintenance. Please refer to the Kubota and Leroy
Somer manuals as well as "Service and Maintenance of the Generator ", page 48 for more information on
maintenance of the generator.
Used oil in the B-16 Mobile LED
Oil used in the generator is 10 W 40 for ambient temperature up to -20°C.
Hydraulic oil is SAE 35
R59770490 B-16 MOBILE LED 07/01/2010
Daily
500 km
C
L
T
Cl
C
L
5. Maintenance, Service
Quarterly
T
Cl
C
L
T
Cl
Yearly
C
L
T
Cl