11. Maintenance
Pump solvent out of the machine
Pressure side of the pump:
Start program P68 (empty tank I)
Start program P69 (empty tank II)
Start program P70 (empty tank III)
If the tank does not empty out, you must start the required program again.

11.5 Maintenance Work Instructions

Note that after cleaning the solvent tanks:
If you opened any covers, sight-glasses or doors, you must check
them for leaks when you fill the tanks again.
Make sure that the machine is turned off and secured before performing any maintenance
work.
Observe safety regulations concerning the handling of solvent (see Point 2).
Only trained service personnel who are familiar with the machine are authorized to perform
maintenance work.

11.5.1 Lint Filter/Button Trap

The button trap and lint filter are combined in a common maintenance unit with a single maintenance
opening.
Maintenance of the lint filter and the needle seat should be carried out daily prior to the first and after
the last cleaning charges (but only after P34 has been run!)
Sequence of the maintenance work on the lint filter:
Loosen the cover fastener and open the cover.
Remove the lint filter basket.
Remove and clean the lint filter mat from the filter basket (wash if necessary).
Check the lint filter mat for any damage.
Place cleaned lint filter mat on to the filter basket and secure properly.
Attention: Never work without the lint filter insert and never use
-
Then perform the button trap maintenance.
Remove cap
Connect hose to barrel
damaged lint filter mats.