6.
Operation
Execution:
Connect a hose between the barrel and ball valve (1).
Connect the gas displacement line between the barrel and water separator (2).
Open ball valve (1).
Start program P51:
5
PROG
+
The tanks fill up, with one overflowing into the other.
Watch the level of the liquid in the tank at the sight-glass until the tanks are full enough.
Lift the suction line out of the barrel.
Close the ball valve (1).
Stop program P51 and leave:
+
PROG
STOP
Remove the hose connections to the barrel.
Put the screw cap on to the ball valve (1).
Close the barrel and store in accordance with regulations.
Depending on the filter you have, you may have to refill with solvent after you fill the filter.
If the barrel becomes empty during the filling, do the following:
Close the ball valve (1).
Stop program P51:
STOP
Change the barrel.
Open the ball valve (1).
Continue program P51:
START
6.1.3 Refilling Solvent
Follow the procedure given in Point 6.1.2 for routine refilling of solvent.
Attention: Even empty containers can still hold solvent residues.
1
START
+
+
C
+
+
HOLD
Therefore, tightly seal the container (barrel) again and
store or dispose of in accordance with regulations!
20
C
+
6.
P21/P26/P30