BÖWE P26 Instruction Manual page 20

Hide thumbs Also See for P26:
Table of Contents

Advertisement

4.
Technical Specifications
P21
Heating
Other:
Dist. throughput (DIN 11916) max.
Filter throughput
Filter surface, economy filter 1
Filter surface, economy filter 2
Weight without solvent
(with 2 economy filters, 2 cartridge filters,
Slimsorba)
Weight with solvent
(with 2 economy filters, 2 cartridge filters,
Slimsorba)
Floor space
Floor surface **
Cage centrifugal force
Floor load, stat. and dyn.
Noise level
Heat balance: *
Heat to dissipate
via cooling water ***:
Heat dissipated to the surroundings:
*
Values apply to a standard 2-bath load, 1
cooling water inlet temperature + 12 °C (53.6 °F), steam supply 4 – 5 bar (58.0 - 72.5 psi) overpressure
saturated steam, ambient temperature 5 to + 40 °C (41 to 104 °F)
**
For portion of the floor surface for force transmission, see Installation Instructions, Point 5.3.1
***
Refers to water without additives
Subject to change!
13
l/h (US gal/h)
240 (63.4)
l/h (US gal/h)
5000 (1320)
2
2
m
(ft
)
2
2
m
(ft
)
kg (lb)
2025 (4465)
kg (lb)
2890 (6372)
2
2
m
(ft
)
2
2
m
(ft
)
N (lb)
12600 (2832.5) 12600 (2832.5)
2
2
N/m
(lb/ft
)
17500 (365.6)
dB (A)
kJ/cycle
kJ/cycle
st
bath low level for distillation at
Steam
Electric
180 (47.6)
5000 (1320)
5.0 (53.8)
5.0 (53.8)
3.5 (37.7)
3.5 (37.7)
2025 (4465)
2890 (6372)
3.3 (35.5)
3.3 (35.5)
2.3 (24.8)
2.3 (24.8)
17500 (365.6)
62
33800
33800
8400
4.
62
8400
P21/P26/P30

Advertisement

Table of Contents
loading

This manual is also suitable for:

P21P30

Table of Contents