11. Maintenance

Attention: Warranty claims will only be accepted if maintenance has

11.1 Operation and Maintenance Summary

When starting operation:
Turn on steam supply
Turn on room ventilation system
Turn on cooling water supply
Turn on compressed air supply
Open condensate valve
Turn on machine main switch
Start deodorizing program P43, press
"STOP" button when program ends and
signal sounds
When stopping operation:
Turn off machine main switch
Turn off steam supply
Close condensate valve
Turn off cooling water supply
Turn off compressed air supply cooling
compressor
Turn off room ventilation system or switch to
night operation
Inspection and maintenance work:
Daily: (before starting the first cycle)
Check machine for leaks
Check solvent safety trough for solvent
If necessary, add neutralization agent to still
Clean button trap strainer and lint filter
11.5.1)
Check safety separator, if necessary, dispose
of process water in accordance with the
regulations that apply in your country
Check the liquid level of the cleaning
agent container
Machine is ready for operation
Daily: (after the last cycle)
Execute distillation maintenance program
P45
(Alternatively start with 15 E during the last
charge)
58
been performed properly! Follow safety regulations!
All recommendations concerning maintenance are minimum
requirements and refer to a one-shift operation!
(see
Weekly:
Execute multi-maintenance program P49
Drain water from compressed air armature
Clean the sprayer dirt strainers and spray
nozzles
Check the function of the disposal vessel
overfill sensor
Clean the Slimsorba air filter (suction off)
Monthly:
Execute multi-maintenance program P50
Check pH level (7 – 9 indicates good solvent
condition)
Check solvent levels in the tanks
Clean strainers in water and steam feeders
Lubricate cage bearing
Check, clean post-filter
Semi-annually:
Check, clean air cooler
Clean tanks
Retighten screwed unions
Check V-belt tension, re-tension
Replace carbon in venting and aeration filters
Annually:
Machine inspection (according to BGR 500
chapter 2.14)
Remove filter discs and clean in the machine
(program P6)
Check sacrificial anodes, replace if
necessary
Check Slimsorba activated carbon
Check, clean back wall of cage
Attention:
Close the loading door and maintenance
openings again immediately
Use only lithium-based lubricating
greases, such as:
- ALVANIA 3 (SHELL)
- BEACON 2 (ESSO)
11.
11.1
- MARSON L2 (FINA)
- LGMT 3 (SKF)