28
7.
Functional Units
7.

7.3 Solvent Cooling System (Optional Equipment)

7.3
A heat exchanger, which is cooled by cooling agent, cools the detergent solution. The cooling of the
solvent is set to 20 °C (68 °F) in gentle programs. The cooling is controlled over a thermal sensor at
the input to the heat exchanger. During each bath with detergent solution cooling, the
program remains stopped before pumping up (the cage does not move) until the selected detergent
solution temperature has been reached (with water cooling, a max. of 3 minutes). Then the detergent
solution temperature is monitored while the program runs.
Cooled with a cooling agent:
707760-22-0
1 Solvent cooling system
2 Cooling agent inlet
3 Cooling agent outlet
4 Thermal sensor
5 Bypass without cooling
P21/P26/P30