Machine
Basic values:
Steam pressure (saturated steam)
Steam temperature (max. permitted)
Cooling water pressure
Low cooling water level switch
Cooling water temperature, max.
Compressed air
Low air pressure switch (if present)
Cage speeds:
Cleaning /drying
Spinning
Reversing cycle (cleaning)
Low level
High level
Pump pressure (max.)
Filter surface, economy filter
Filter powder (only for machines
without emission-free still rake out
system)
Tank I: optimum filling volume (high
level)
Detergent solution cooler:*
Detergent solution thermal sensor:
Detergent solution cooler ON
17
P21
bar
4 – 5
(psi)
(58.0 – 72.5)
°C
150
(°F)
(302)
bar
2 – 4
(psi)
(29.0 – 58.0)
bar
(psi)
(29.0)
°C
(°F)
(77)
bar
(psi)
(87.0)
bar
(psi)
(58.0)
RPM
RPM
400 /500
sec.
10 /5 /10
l
52.5
(US gal)
(13.9)
l
105
(US gal)
(27.7)
bar
(psi)
(36.3)
2
m
2
(ft
)
(53.8)
kg
(lb)
(5.5)
l
110
(US gal)
(29.0)
°C
15 – 30
(°F)
(59 – 86)
P26
4 – 5
(58.0 – 72.5)
150
(302)
2 – 4
(29.0 – 58.0)
2
2
(29.0)
25
25
(77)
6
6
(87.0)
4
4
(58.0)
35
35
400 /500
10 /5 /10
65
(17.2)
130
(34.3)
2.5
2.5
(36.3)
5.0
5.0
(53.8)
2.5
2.5
(5.5)
135
(35.6)
15 – 30
(59 – 86)
5.
P30
4 - 5
(58.0 – 72.5)
150
(302)
2 – 4
(29.0 – 58.0)
2
(29.0)
25
(77)
6
(87.0)
4
(58.0)
35
400 /500
10 /5 /10
75
(19.8)
150
(39.6)
2.5
(36.3)
5.0
(53.8)
2.5
(5.5)
155
(40.9)
15 – 30
(59 – 86)