How To Adjust A Single Cam; Travel Limit Cams And Signaling Cams - Milton Roy MAXROY Series Actuator Capacity Control Manual

Table of Contents

Advertisement

12.2 How to adjust a single cam?

Make sure the cams contact the switch according to their
proper direction of travel, otherwise you could damage the
switch.
At the desired position of the actuator output:
Figure 13. Setting Cam

12.3 Travel limit cams and signaling cams

On ACC actuator, you have 4
cams with 2 different functions:
Travel limit cams cut motor
power
supply
trigger
corresponding
position.
Signaling cams are not wired
by default. You can use them
to indicate when the actuator
gets close to an end position.
Signaling cams must be set to
reach their corresponding switch
before the travel limit cams do.
If the actuator is supplied mounted on a pump, following
settings should have been performed by Milton Roy.
when
they
the
switches
to
an
end
Page 28 of 33
/
English
1) Turn the setting screw of
the
corresponding
with a flat-head or a
Phillips-head screwdriver.
The cam disk is then turning.
2) Set the cam disk until you
hear a click from the
switch. It indicates the
triggering of the switch.
Figure 14. Setting Cam
cam

Hide quick links:

Advertisement

Table of Contents
loading