6.5 Returning units to the factory.

The Actuator Capacity Control (ACC) units will not be accepted for
repair without a Return Material Authorization, available from the
Factory Repair Department. If the ACC is being returned attached to
a pump, process liquid should be flushed from the pump liquid end
and oil should be drained from the pump housing before the pump is
shipped. Label the unit clearly to indicate the liquid being pumped.
NOTE
Federal law prohibits handling of equipment that is not
accompanied by an OSHA Safety Data Sheet (SDS). A completed
SDS must be packed in the shipping crate if the ACC is returned
attached to a pump. These safety precautions will aid the
troubleshooting and repair procedure and preclude serious injury
to repair personnel from hazardous residue in pump liquid end.
All inquiries or parts orders should be addressed
to your local Milton Roy representative.
Representatives can be found on our website
(www.miltonroy.com).

6.6 Trouble shooting.

SYMPTOMS
ACC moves to
same position
regardless of
signal applied
/
English
● Improper command signal applied to ACC.
Connect mA meter into signal line. Read signal. If
necessary, correct signal source, possible broken
wire, loose connection, etc.
● Mode setup incorrect. Review ini al start-up
procedure.
Page 18 of 33
REMEDIES