Electrical And Temperature Parameters; Special Operation Conditions Including Incorrect Practices - Milton Roy MAXROY Series Actuator Capacity Control Manual

Table of Contents

Advertisement

Groups
This actuator has been designed for the surface industries groups B,
C or D.
Zone
Division
Group
Group
D
IIA
C
IIB
E
Not
available
on ACC
G
For other gases, please consult a notified body (e.g. CSA or INERIS).
Temperature
The temperature class corresponds to the actuator maximum surface
temperature.
Class
T6
Check group and temperature class on the actuator tag.
6.2

Electrical and temperature parameters.

The power supply voltage and frequency are indicated on the name
plates and (or) on the electric wiring diagram.
The minimum ambient temperature is -4°F (-20°C) and the maximum
+140°F (60°C) unless another information is mentioned on the name
plates.
6.3
Special operation conditions including incorrect
practices.
Duty cycle: Motors are designed for an intermittent operation; it means
that they should be stopped for a sufficient period of time after each
operation in order to enable it to cool down (see table 2).
Combustible Carbonaceous Dusts
F
Table 4: Zone group ACC design
Max surface temperature
Table 5 : Temperature class
Page 16 of 33
/
English
Typical gas
Propane
Ethylene
Combustible Metal Dusts
Other Combustible Dusts
185°F (85°C)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents